Pore size estimation in axon-mimicking microfibers with diffusion-relaxation MRI.

Details

Ressource 1Download: 38192108.pdf (4216.65 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_BB87D99B958C
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Pore size estimation in axon-mimicking microfibers with diffusion-relaxation MRI.
Journal
Magnetic resonance in medicine
Author(s)
Canales-Rodríguez E.J., Pizzolato M., Zhou F.L., Barakovic M., Thiran J.P., Jones D.K., Parker GJM, Dyrby T.B.
ISSN
1522-2594 (Electronic)
ISSN-L
0740-3194
Publication state
Published
Issued date
06/2024
Peer-reviewed
Oui
Volume
91
Number
6
Pages
2579-2596
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
This study aims to evaluate two distinct approaches for fiber radius estimation using diffusion-relaxation MRI data acquired in biomimetic microfiber phantoms that mimic hollow axons. The methods considered are the spherical mean power-law approach and a T <sub>2</sub> -based pore size estimation technique.
A general diffusion-relaxation theoretical model for the spherical mean signal from water molecules within a distribution of cylinders with varying radii was introduced, encompassing the evaluated models as particular cases. Additionally, a new numerical approach was presented for estimating effective radii (i.e., MRI-visible mean radii) from the ground truth radii distributions, not reliant on previous theoretical approximations and adaptable to various acquisition sequences. The ground truth radii were obtained from scanning electron microscope images.
Both methods show a linear relationship between effective radii estimated from MRI data and ground-truth radii distributions, although some discrepancies were observed. The spherical mean power-law method overestimated fiber radii. Conversely, the T <sub>2</sub> -based method exhibited higher sensitivity to smaller fiber radii, but faced limitations in accurately estimating the radius in one particular phantom, possibly because of material-specific relaxation changes.
The study demonstrates the feasibility of both techniques to predict pore sizes of hollow microfibers. The T <sub>2</sub> -based technique, unlike the spherical mean power-law method, does not demand ultra-high diffusion gradients, but requires calibration with known radius distributions. This research contributes to the ongoing development and evaluation of neuroimaging techniques for fiber radius estimation, highlights the advantages and limitations of both methods, and provides datasets for reproducible research.
Keywords
T2 relaxometry, biomimetic phantoms, diffusion MRI, fiber radius, microstructure
Pubmed
Web of science
Open Access
Yes
Create date
12/01/2024 12:47
Last modification date
09/04/2024 7:24
Usage data