Reducing False Alarms in Wearable Seizure Detection With EEGformer: A Compact Transformer Model for MCUs.

Details

Ressource 1Download: 38261487.pdf (2718.76 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_BA31F50F7689
Type
Article: article from journal or magazin.
Publication sub-type
Review (review): journal as complete as possible of one specific subject, written based on exhaustive analyses from published work.
Collection
Publications
Institution
Title
Reducing False Alarms in Wearable Seizure Detection With EEGformer: A Compact Transformer Model for MCUs.
Journal
IEEE transactions on biomedical circuits and systems
Author(s)
Busia P., Cossettini A., Ingolfsson T.M., Benatti S., Burrello A., Jung VJB, Scherer M., Scrugli M.A., Bernini A., Ducouret P., Ryvlin P., Meloni P., Benini L.
ISSN
1940-9990 (Electronic)
ISSN-L
1932-4545
Publication state
Published
Issued date
06/2024
Peer-reviewed
Oui
Volume
18
Number
3
Pages
608-621
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
The long-term, continuous analysis of electroencephalography (EEG) signals on wearable devices to automatically detect seizures in epileptic patients is a high-potential application field for deep neural networks, and specifically for transformers, which are highly suited for end-to-end time series processing without handcrafted feature extraction. In this work, we propose a small-scale transformer detector, the EEGformer, compatible with unobtrusive acquisition setups that use only the temporal channels. EEGformer is the result of a hardware-oriented design exploration, aiming for efficient execution on tiny low-power micro-controller units (MCUs) and low latency and false alarm rate to increase patient and caregiver acceptance.Tests conducted on the CHB-MIT dataset show a 20% reduction of the onset detection latency with respect to the state-of-the-art model for temporal acquisition, with a competitive 73% seizure detection probability and 0.15 false-positive-per-hour (FP/h). Further investigations on a novel and challenging scalp EEG dataset result in the successful detection of 88% of the annotated seizure events, with 0.45 FP/h.We evaluate the deployment of the EEGformer on three commercial low-power computing platforms: the single-core Apollo4 MCU and the GAP8 and GAP9 parallel MCUs. The most efficient implementation (on GAP9) results in as low as 13.7 ms and 0.31 mJ per inference, demonstrating the feasibility of deploying the EEGformer on wearable seizure detection systems with reduced channel count and multi-day battery duration.
Keywords
Humans, Electroencephalography/instrumentation, Electroencephalography/methods, Wearable Electronic Devices, Seizures/diagnosis, Seizures/physiopathology, Signal Processing, Computer-Assisted/instrumentation, Algorithms, Neural Networks, Computer
Pubmed
Web of science
Open Access
Yes
Create date
25/07/2024 17:14
Last modification date
26/07/2024 7:16
Usage data