Descemet stripping automated endothelial keratoplasty tissue preparation with femtosecond laser and contact lens.
Details
Serval ID
serval:BIB_9B16AFD5C329
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Descemet stripping automated endothelial keratoplasty tissue preparation with femtosecond laser and contact lens.
Journal
Cornea
ISSN
1536-4798 (Electronic)
ISSN-L
0277-3740
Publication state
Published
Issued date
01/2010
Peer-reviewed
Oui
Volume
29
Number
1
Pages
93-98
Language
english
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Publication Status: ppublish
Abstract
To report a novel method of preparing planar Descemet stripping automated endothelial keratoplasty (DSAEK) tissue using a femtosecond laser with a hyperopic soft contact lens (Hyp-SCL).
DSAEK tissue was prepared from 11 cadaveric porcine eyes. A femtosecond laser was used to create 400-microm flaps, with or without a Hyp-SCL, after which the eyes were imaged with anterior segment optical coherence tomography. The ratio of the mean central thickness (C) to the mean peripheral thickness (P) was calculated using the flap tool.
Eleven eyes were cut (5 without, 5 with, and 1 without and with a Hyp-SCL). In all corneas, the cut interfaces were visualized by anterior segment optical coherence tomography. The mean C:P ratio of the flap made without a Hyp-SCL was 0.998 (range 0.968-1.03, SD = 0.254) compared with 0.904 (range 0.851-0.985, SD = 0.509) with a Hyp-SCL (P = 0.001), demonstrating that a cut made with a Hyp-SCL created a flap that was significantly more concave than that created without a Hyp-SCL, resulting in a more planar DSAEK graft. However, the C:P ratios calculated for DSAEK tissue made without (mean 0.998, range 0.965-1.02, SD = 0.0195) and with (mean 1.02, range 0.986-1.05, SD = 0.0250) a Hyp-SCL did not show significance (P = 0.07).
Combining a femtosecond laser and a Hyp-SCL may aid in the creation of planar donor tissue for DSAEK. Clinically, this could reduce the amount of postoperative hyperopic shift, although further human corneal studies are warranted.
DSAEK tissue was prepared from 11 cadaveric porcine eyes. A femtosecond laser was used to create 400-microm flaps, with or without a Hyp-SCL, after which the eyes were imaged with anterior segment optical coherence tomography. The ratio of the mean central thickness (C) to the mean peripheral thickness (P) was calculated using the flap tool.
Eleven eyes were cut (5 without, 5 with, and 1 without and with a Hyp-SCL). In all corneas, the cut interfaces were visualized by anterior segment optical coherence tomography. The mean C:P ratio of the flap made without a Hyp-SCL was 0.998 (range 0.968-1.03, SD = 0.254) compared with 0.904 (range 0.851-0.985, SD = 0.509) with a Hyp-SCL (P = 0.001), demonstrating that a cut made with a Hyp-SCL created a flap that was significantly more concave than that created without a Hyp-SCL, resulting in a more planar DSAEK graft. However, the C:P ratios calculated for DSAEK tissue made without (mean 0.998, range 0.965-1.02, SD = 0.0195) and with (mean 1.02, range 0.986-1.05, SD = 0.0250) a Hyp-SCL did not show significance (P = 0.07).
Combining a femtosecond laser and a Hyp-SCL may aid in the creation of planar donor tissue for DSAEK. Clinically, this could reduce the amount of postoperative hyperopic shift, although further human corneal studies are warranted.
Keywords
Animals, Contact Lenses, Hydrophilic, Descemet Stripping Endothelial Keratoplasty, Laser Therapy/methods, Specimen Handling/methods, Swine, Tomography, Optical Coherence
Pubmed
Web of science
Create date
01/10/2019 15:42
Last modification date
06/10/2019 5:26