Descemet stripping automated endothelial keratoplasty tissue preparation with femtosecond laser and contact lens.
Détails
ID Serval
serval:BIB_9B16AFD5C329
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Descemet stripping automated endothelial keratoplasty tissue preparation with femtosecond laser and contact lens.
Périodique
Cornea
ISSN
1536-4798 (Electronic)
ISSN-L
0277-3740
Statut éditorial
Publié
Date de publication
01/2010
Peer-reviewed
Oui
Volume
29
Numéro
1
Pages
93-98
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Publication Status: ppublish
Résumé
To report a novel method of preparing planar Descemet stripping automated endothelial keratoplasty (DSAEK) tissue using a femtosecond laser with a hyperopic soft contact lens (Hyp-SCL).
DSAEK tissue was prepared from 11 cadaveric porcine eyes. A femtosecond laser was used to create 400-microm flaps, with or without a Hyp-SCL, after which the eyes were imaged with anterior segment optical coherence tomography. The ratio of the mean central thickness (C) to the mean peripheral thickness (P) was calculated using the flap tool.
Eleven eyes were cut (5 without, 5 with, and 1 without and with a Hyp-SCL). In all corneas, the cut interfaces were visualized by anterior segment optical coherence tomography. The mean C:P ratio of the flap made without a Hyp-SCL was 0.998 (range 0.968-1.03, SD = 0.254) compared with 0.904 (range 0.851-0.985, SD = 0.509) with a Hyp-SCL (P = 0.001), demonstrating that a cut made with a Hyp-SCL created a flap that was significantly more concave than that created without a Hyp-SCL, resulting in a more planar DSAEK graft. However, the C:P ratios calculated for DSAEK tissue made without (mean 0.998, range 0.965-1.02, SD = 0.0195) and with (mean 1.02, range 0.986-1.05, SD = 0.0250) a Hyp-SCL did not show significance (P = 0.07).
Combining a femtosecond laser and a Hyp-SCL may aid in the creation of planar donor tissue for DSAEK. Clinically, this could reduce the amount of postoperative hyperopic shift, although further human corneal studies are warranted.
DSAEK tissue was prepared from 11 cadaveric porcine eyes. A femtosecond laser was used to create 400-microm flaps, with or without a Hyp-SCL, after which the eyes were imaged with anterior segment optical coherence tomography. The ratio of the mean central thickness (C) to the mean peripheral thickness (P) was calculated using the flap tool.
Eleven eyes were cut (5 without, 5 with, and 1 without and with a Hyp-SCL). In all corneas, the cut interfaces were visualized by anterior segment optical coherence tomography. The mean C:P ratio of the flap made without a Hyp-SCL was 0.998 (range 0.968-1.03, SD = 0.254) compared with 0.904 (range 0.851-0.985, SD = 0.509) with a Hyp-SCL (P = 0.001), demonstrating that a cut made with a Hyp-SCL created a flap that was significantly more concave than that created without a Hyp-SCL, resulting in a more planar DSAEK graft. However, the C:P ratios calculated for DSAEK tissue made without (mean 0.998, range 0.965-1.02, SD = 0.0195) and with (mean 1.02, range 0.986-1.05, SD = 0.0250) a Hyp-SCL did not show significance (P = 0.07).
Combining a femtosecond laser and a Hyp-SCL may aid in the creation of planar donor tissue for DSAEK. Clinically, this could reduce the amount of postoperative hyperopic shift, although further human corneal studies are warranted.
Mots-clé
Animals, Contact Lenses, Hydrophilic, Descemet Stripping Endothelial Keratoplasty, Laser Therapy/methods, Specimen Handling/methods, Swine, Tomography, Optical Coherence
Pubmed
Web of science
Création de la notice
01/10/2019 15:42
Dernière modification de la notice
06/10/2019 5:26