A priori quality assurance using a benchmark case of the randomized phase 2 GORTEC 2014-14 in oligometastatic head and neck cancer patients.

Details

Serval ID
serval:BIB_770454ACEC36
Type
Article: article from journal or magazin.
Publication sub-type
Review (review): journal as complete as possible of one specific subject, written based on exhaustive analyses from published work.
Collection
Publications
Institution
Title
A priori quality assurance using a benchmark case of the randomized phase 2 GORTEC 2014-14 in oligometastatic head and neck cancer patients.
Journal
Cancer radiotherapie
Author(s)
Khalladi N., Dejean C., Bosset M., Pointreau Y., Kinj R., Racadot S., Castelli J., Huguet F., Renard S., Guihard S., Tao Y., Rouvier J.M., Johnson A., Bourhis J., Xu Shan S., Thariat J.
ISSN
1769-6658 (Electronic)
ISSN-L
1278-3218
Publication state
Published
Issued date
12/2021
Peer-reviewed
Oui
Volume
25
Number
8
Pages
755-762
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
A Benchmark Case (BC) was performed as part of the quality assurance process of the randomized phase 2 GORTEC 2014-14 OMET study, testing the possibility of multisite stereotactic radiation therapy (SBRT) alone in oligometastatic head and neck squamous cell carcinoma (HNSCC) as an alternative to systemic treatment and SBRT.
Compliance of the investigating centers with the prescription, delineation, planning and evaluation recommendations available in the research protocol was assessed. In addition, classical dosimetric analysis was supplemented by quantitative geometric analysis using conformation indices.
Twenty centers participated in the BC analysis. Among them, four major deviations (MaD) were reported in two centers. Two (10%) centers in MaD had omitted the satellite tumor nodule and secondarily validated after revision. Their respective DICE indexes were 0.37 and 0 and use of extracranial SBRT devices suboptimal There were significant residual heterogeneities between participating centers, including those with a similar SBRT equipment, with impact of plan quality using standard indicators and geometric indices.
A priori QA using a BC conditioning the participation of the clinical investigation centers showed deviations from good SBRT practice and led to the exclusion of one out of the twenty participating centers. The majority of centers have demonstrated rigorous compliance with the research protocol. The use of quality indexes adds a complementary approach to improve assessment of plan quality.