Near-real-time Mueller polarimetric image processing for neurosurgical intervention.

Details

Ressource 1Download: 38503943.pdf (6157.58 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_3293FB474611
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Near-real-time Mueller polarimetric image processing for neurosurgical intervention.
Journal
International journal of computer assisted radiology and surgery
Author(s)
Moriconi S., Rodríguez-Núñez O., Gros R., Felger L.A., Maragkou T., Hewer E., Pierangelo A., Novikova T., Schucht P., McKinley R.
ISSN
1861-6429 (Electronic)
ISSN-L
1861-6410
Publication state
Published
Issued date
06/2024
Peer-reviewed
Oui
Volume
19
Number
6
Pages
1033-1043
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
Wide-field imaging Mueller polarimetry is a revolutionary, label-free, and non-invasive modality for computer-aided intervention; in neurosurgery, it aims to provide visual feedback of white matter fibre bundle orientation from derived parameters. Conventionally, robust polarimetric parameters are estimated after averaging multiple measurements of intensity for each pair of probing and detected polarised light. Long multi-shot averaging, however, is not compatible with real-time in vivo imaging, and the current performance of polarimetric data processing hinders the translation to clinical practice.
A learning-based denoising framework is tailored for fast, single-shot, noisy acquisitions of polarimetric intensities. Also, performance-optimised image processing tools are devised for the derivation of clinically relevant parameters. The combination recovers accurate polarimetric parameters from fast acquisitions with near-real-time performance, under the assumption of pseudo-Gaussian polarimetric acquisition noise.
The denoising framework is trained, validated, and tested on experimental data comprising tumour-free and diseased human brain samples in different conditions. Accuracy and image quality indices showed significant ( ) improvements on testing data for a fast single-pass denoising versus the state-of-the-art and high polarimetric image quality standards. The computational time is reported for the end-to-end processing.
The end-to-end image processing achieved real-time performance for a localised field of view ( ). The denoised polarimetric intensities produced visibly clear directional patterns of neuronal fibre tracts in line with reference polarimetric image quality standards; directional disruption was kept in case of neoplastic lesions. The presented advances pave the way towards feasible oncological neurosurgical translations of novel, label-free, interventional feedback.
Keywords
Humans, Neurosurgical Procedures/methods, Image Processing, Computer-Assisted/methods, Brain Neoplasms/surgery, Brain Neoplasms/diagnostic imaging, Surgery, Computer-Assisted/methods, White Matter/diagnostic imaging, White Matter/surgery, AI, Mueller polarimetric imaging, Neurosurgery, Real-time denoising