Cryo-negative staining: advantages and applications for three-dimensional electron microscopy of biological macromolecules

Details

Ressource 1 Under indefinite embargo.
UNIL restricted access
State: Public
Version: After imprimatur
License: Not specified
Serval ID
serval:BIB_R_484
Type
PhD thesis: a PhD thesis.
Collection
Publications
Institution
Title
Cryo-negative staining: advantages and applications for three-dimensional electron microscopy of biological macromolecules
Author(s)
De Carlo S.
Director(s)
Dubochet J.
Institution details
Université de Lausanne, Faculté des sciences
Address
Décanat Géosciences, Collège Propédeutique 1, 1015 Lausanne
Publication state
Accepted
Issued date
2002
Language
english
Notes
Prof. Giovanni Dietler, Président ; Prof. Jacques Dubochet, Directeur de thèse ; Dr. Nicolas Boisset (LMCP, Paris), Expert ; Dr. Andreas Hoenger (EMBL, Heidelberg), Expert
Abstract
Les échantillons biologiques ne s?arrangent pas toujours en objets ordonnés (cristaux 2D ou hélices) nécessaires pour la microscopie électronique ni en cristaux 3D parfaitement ordonnés pour la cristallographie rayons X alors que de nombreux spécimens sont tout simplement trop << gros D pour la spectroscopie NMR. C?est pour ces raisons que l?analyse de particules isolées par la cryo-microscopie électronique est devenue une technique de plus en plus importante pour déterminer la structure de macromolécules. Néanmoins, le faible rapport signal-sur-bruit ainsi que la forte sensibilité des échantillons biologiques natifs face au faisceau électronique restent deux parmi les facteurs limitant la résolution. La cryo-coloration négative est une technique récemment développée permettant l?observation des échantillons biologiques avec le microscope électronique. Ils sont observés à l?état vitrifié et à basse température, en présence d?un colorant (molybdate d?ammonium). Les avantages de la cryo-coloration négative sont étudiés dans ce travail. Les résultats obtenus révèlent que les problèmes majeurs peuvent êtres évités par l?utilisation de cette nouvelle technique. Les échantillons sont représentés fidèlement avec un SNR 10 fois plus important que dans le cas des échantillons dans l?eau. De plus, la comparaison de données obtenues après de multiples expositions montre que les dégâts liés au faisceau électronique sont réduits considérablement. D?autre part, les résultats exposés mettent en évidence que la technique est idéale pour l?analyse à haute résolution de macromolécules biologiques. La solution vitrifiée de molybdate d?ammonium entourant l?échantillon n?empêche pas l?accès à la structure interne de la protéine. Finalement, plusieurs exemples d?application démontrent les avantages de cette technique nouvellement développée.<br/><br/>Many biological specimens do not arrange themselves in ordered assemblies (tubular or flat 2D crystals) suitable for electron crystallography, nor in perfectly ordered 3D crystals for X-ray diffraction; many other are simply too large to be approached by NMR spectroscopy. Therefore, single-particles analysis has become a progressively more important technique for structural determination of large isolated macromolecules by cryo-electron microscopy. Nevertheless, the low signal-to-noise ratio and the high electron-beam sensitivity of biological samples remain two main resolution-limiting factors, when the specimens are observed in their native state. Cryo-negative staining is a recently developed technique that allows the study of biological samples with the electron microscope. The samples are observed at low temperature, in the vitrified state, but in presence of a stain (ammonium molybdate). In the present work, the advantages of this novel technique are investigated: it is shown that cryo-negative staining can generally overcome most of the problems encountered with cryo-electron microscopy of vitrified native suspension of biological particles. The specimens are faithfully represented with a 10-times higher SNR than in the case of unstained samples. Beam-damage is found to be considerably reduced by comparison of multiple-exposure series of both stained and unstained samples. The present report also demonstrates that cryo-negative staining is capable of high- resolution analysis of biological macromolecules. The vitrified stain solution surrounding the sample does not forbid the access to the interna1 features (ie. the secondary structure) of a protein. This finding is of direct interest for the structural biologist trying to combine electron microscopy and X-ray data. developed electron microscopy technique. Finally, several application examples demonstrate the advantages of this newly
Create date
09/12/2009 10:48
Last modification date
08/04/2020 5:19
Usage data