Predictive performance of automated surveillance algorithms for intravascular catheter bloodstream infections: a systematic review and meta-analysis.
Details
Serval ID
serval:BIB_FA5A93D7B3B3
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Predictive performance of automated surveillance algorithms for intravascular catheter bloodstream infections: a systematic review and meta-analysis.
Journal
Antimicrobial resistance and infection control
Working group(s)
Swissnoso
Contributor(s)
Balmelli C., Berthod D., Marschall J., Sax H., Schlegel M., Schweiger A., Senn L., Sommerstein R., Troillet N., Gysin D.V., Widmer A.F., Wolfensberger A., Zingg W.
ISSN
2047-2994 (Electronic)
ISSN-L
2047-2994
Publication state
Published
Issued date
31/08/2023
Peer-reviewed
Oui
Volume
12
Number
1
Pages
87
Language
english
Notes
Publication types: Meta-Analysis ; Systematic Review ; Journal Article ; Review ; Research Support, Non-U.S. Gov't
Publication Status: epublish
Publication Status: epublish
Abstract
Intravascular catheter infections are associated with adverse clinical outcomes. However, a significant proportion of these infections are preventable. Evaluations of the performance of automated surveillance systems for adequate monitoring of central-line associated bloodstream infection (CLABSI) or catheter-related bloodstream infection (CRBSI) are limited.
We evaluated the predictive performance of automated algorithms for CLABSI/CRBSI detection, and investigated which parameters included in automated algorithms provide the greatest accuracy for CLABSI/CRBSI detection.
We performed a meta-analysis based on a systematic search of published studies in PubMed and EMBASE from 1 January 2000 to 31 December 2021. We included studies that evaluated predictive performance of automated surveillance algorithms for CLABSI/CRBSI detection and used manually collected surveillance data as reference. We estimated the pooled sensitivity and specificity of algorithms for accuracy and performed a univariable meta-regression of the different parameters used across algorithms.
The search identified five full text studies and 32 different algorithms or study populations were included in the meta-analysis. All studies analysed central venous catheters and identified CLABSI or CRBSI as an outcome. Pooled sensitivity and specificity of automated surveillance algorithm were 0.88 [95%CI 0.84-0.91] and 0.86 [95%CI 0.79-0.92] with significant heterogeneity (I <sup>2</sup> = 91.9, p < 0.001 and I <sup>2</sup> = 99.2, p < 0.001, respectively). In meta-regression, algorithms that include results of microbiological cultures from specific specimens (respiratory, urine and wound) to exclude non-CRBSI had higher specificity estimates (0.92, 95%CI 0.88-0.96) than algorithms that include results of microbiological cultures from any other body sites (0.88, 95% CI 0.81-0.95). The addition of clinical signs as a predictor did not improve performance of these algorithms with similar specificity estimates (0.92, 95%CI 0.88-0.96).
Performance of automated algorithms for detection of intravascular catheter infections in comparison to manual surveillance seems encouraging. The development of automated algorithms should consider the inclusion of results of microbiological cultures from specific specimens to exclude non-CRBSI, while the inclusion of clinical data may not have an added-value. Trail Registration Prospectively registered with International prospective register of systematic reviews (PROSPERO ID CRD42022299641; January 21, 2022). https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42022299641.
We evaluated the predictive performance of automated algorithms for CLABSI/CRBSI detection, and investigated which parameters included in automated algorithms provide the greatest accuracy for CLABSI/CRBSI detection.
We performed a meta-analysis based on a systematic search of published studies in PubMed and EMBASE from 1 January 2000 to 31 December 2021. We included studies that evaluated predictive performance of automated surveillance algorithms for CLABSI/CRBSI detection and used manually collected surveillance data as reference. We estimated the pooled sensitivity and specificity of algorithms for accuracy and performed a univariable meta-regression of the different parameters used across algorithms.
The search identified five full text studies and 32 different algorithms or study populations were included in the meta-analysis. All studies analysed central venous catheters and identified CLABSI or CRBSI as an outcome. Pooled sensitivity and specificity of automated surveillance algorithm were 0.88 [95%CI 0.84-0.91] and 0.86 [95%CI 0.79-0.92] with significant heterogeneity (I <sup>2</sup> = 91.9, p < 0.001 and I <sup>2</sup> = 99.2, p < 0.001, respectively). In meta-regression, algorithms that include results of microbiological cultures from specific specimens (respiratory, urine and wound) to exclude non-CRBSI had higher specificity estimates (0.92, 95%CI 0.88-0.96) than algorithms that include results of microbiological cultures from any other body sites (0.88, 95% CI 0.81-0.95). The addition of clinical signs as a predictor did not improve performance of these algorithms with similar specificity estimates (0.92, 95%CI 0.88-0.96).
Performance of automated algorithms for detection of intravascular catheter infections in comparison to manual surveillance seems encouraging. The development of automated algorithms should consider the inclusion of results of microbiological cultures from specific specimens to exclude non-CRBSI, while the inclusion of clinical data may not have an added-value. Trail Registration Prospectively registered with International prospective register of systematic reviews (PROSPERO ID CRD42022299641; January 21, 2022). https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42022299641.
Keywords
Humans, Central Venous Catheters, Algorithms, Data Collection, Sepsis, Accuracy, Algorithm, Automated monitoring, CLABSI, CRBSI, Healthcare associated infections, Surveillance
Pubmed
Open Access
Yes
Create date
20/09/2023 10:55
Last modification date
08/08/2024 6:42