Recurrences of ventricular tachycardia after stereotactic arrhythmia radioablation arise outside the treated volume: analysis of the Swiss cohort.

Details

Ressource 1Download: 37695314_BIB_F98C44DB404D.pdf (20229.31 [Ko])
State: Public
Version: author
License: CC BY-NC 4.0
Serval ID
serval:BIB_F98C44DB404D
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Recurrences of ventricular tachycardia after stereotactic arrhythmia radioablation arise outside the treated volume: analysis of the Swiss cohort.
Journal
Europace
Author(s)
Herrera Siklody C., Schiappacasse L. (co-first), Jumeau R., Reichlin T., Saguner A.M., Andratschke N., Elicin O., Schreiner F., Kovacs B., Mayinger M., Huber A., Verhoeff JJC, Pascale P., Solana Muñoz J., Luca A., Domenichini G., Moeckli R., Bourhis J., Ozsahin E.M., Pruvot E.
ISSN
1532-2092 (Electronic)
ISSN-L
1099-5129
Publication state
Published
Issued date
05/10/2023
Peer-reviewed
Oui
Volume
25
Number
10
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
Stereotactic arrhythmia radioablation (STAR) has been recently introduced for the management of therapy-refractory ventricular tachycardia (VT). VT recurrences have been reported after STAR but the mechanisms remain largely unknown. We analysed recurrences in our patients after STAR.
From 09.2017 to 01.2020, 20 patients (68 ± 8 y, LVEF 37 ± 15%) suffering from refractory VT were enrolled, 16/20 with a history of at least one electrical storm. Before STAR, an invasive electroanatomical mapping (Carto3) of the VT substrate was performed. A mean dose of 23 ± 2 Gy was delivered to the planning target volume (PTV). The median ablation volume was 26 mL (range 14-115) and involved the interventricular septum in 75% of patients. During the first 6 months after STAR, VT burden decreased by 92% (median value, from 108 to 10 VT/semester). After a median follow-up of 25 months, 12/20 (60%) developed a recurrence and underwent a redo ablation. VT recurrence was located in the proximity of the treated substrate in nine cases, remote from the PTV in three cases and involved a larger substrate over ≥3 LV segments in two cases. No recurrences occurred inside the PTV. Voltage measurements showed a significant decrease in both bipolar and unipolar signal amplitude after STAR.
STAR is a new tool available for the treatment of VT, allowing for a significant reduction of VT burden. VT recurrences are common during follow-up, but no recurrences were observed inside the PTV. Local efficacy was supported by a significant decrease in both bipolar and unipolar signal amplitude.
Keywords
Physiology (medical), Cardiology and Cardiovascular Medicine, Ventricular tachycardia, arrhythmogenic substrate, electrical storm, radiofrequency catheter ablation, stereotactic arrhythmia radioablation, toxicity
Pubmed
Web of science
Open Access
Yes
Create date
21/09/2023 10:47
Last modification date
03/03/2024 18:01
Usage data