Comparison of central macular thickness (CMT) measurement between time domain and spectral domain (SD) optical coherence tomography (OCT) and reproducibility of SD OCT in active neovascular AMD

Details

Serval ID
serval:BIB_F8F3ECFB70D6
Type
Inproceedings: an article in a conference proceedings.
Publication sub-type
Abstract (Abstract): shot summary in a article that contain essentials elements presented during a scientific conference, lecture or from a poster.
Collection
Publications
Institution
Title
Comparison of central macular thickness (CMT) measurement between time domain and spectral domain (SD) optical coherence tomography (OCT) and reproducibility of SD OCT in active neovascular AMD
Title of the conference
Joint Congress of SOE/AAO 2011, European Society of Ophthalmology/American Academy of Ophthalmology, 4-7 June, Geneva
Author(s)
Ambresin A., Mantel I., Deli A.
Organization
SOE/AAO
Publication state
Published
Issued date
2011
Pages
FP-RET-067
Language
english
Abstract
Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.
Create date
12/03/2012 11:55
Last modification date
20/08/2019 16:24
Usage data