Refining critical structure contouring in STereotactic Arrhythmia Radioablation (STAR): Benchmark results and consensus guidelines from the STOPSTORM.eu consortium.

Details

Serval ID
serval:BIB_EF6702A9B395
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Refining critical structure contouring in STereotactic Arrhythmia Radioablation (STAR): Benchmark results and consensus guidelines from the STOPSTORM.eu consortium.
Journal
Radiotherapy and oncology
Author(s)
Balgobind B.V., Visser J., Grehn M., Marquard Knap M., de Ruysscher D., Levis M., Alcantara P., Boda-Heggemann J., Both M., Cozzi S., Cvek J., Dieleman EMT, Elicin O., Giaj-Levra N., Jumeau R., Krug D., Algara López M., Mayinger M., Mehrhof F., Miszczyk M., Pérez-Calatayud M.J., van der Pol LHG, van der Toorn P.P., Vitolo V., Postema P.G., Pruvot E., Verhoeff J.C., Blanck O.
ISSN
1879-0887 (Electronic)
ISSN-L
0167-8140
Publication state
Published
Issued date
12/2023
Peer-reviewed
Oui
Volume
189
Pages
109949
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM.eu consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre.
Centres within the STOPSTORM.eu consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95).
Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC = 0.96, median MDA = 0.1 mm and median HD95 = 1.1 mm) and aorta (median DSC = 0.90, median MDA = 0.1 mm and median HD95 = 1.5 mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC = 0.83, median MDA = 0.2 mm and median HD95 = 0.5 mm), valves (median DSC = 0.16, median MDA = 4.6 mm and median HD95 = 16.0 mm), coronary arteries (median DSC = 0.4, median MDA = 0.7 mm and median HD95 = 8.3 mm) and the sinoatrial and atrioventricular nodes (median DSC = 0.29, median MDA = 4.4 mm and median HD95 = 11.4 mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established.
This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established.
Keywords
Humans, Radiotherapy Planning, Computer-Assisted/methods, Benchmarking, Heart, Coronary Vessels, Tachycardia, Ventricular/radiotherapy, Tachycardia, Ventricular/surgery, Cardiac substructures, Contouring benchmark, Organs at risk (OAR), STereotactic Arrhythmia Radioablation (STAR), Stereotactic Body Radiotherapy (SBRT), Ventricular tachycardia (VT)