Pulse Oximetry as an Aid to Rule Out Pneumonia among Patients with a Lower Respiratory Tract Infection in Primary Care.

Details

Ressource 1Download: antibiotics-12-00496.pdf (289.96 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_EA5C7FEC948C
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Pulse Oximetry as an Aid to Rule Out Pneumonia among Patients with a Lower Respiratory Tract Infection in Primary Care.
Journal
Antibiotics
Author(s)
Fischer C., Knüsli J., Lhopitallier L., Tenisch E., Meuwly M.G., Douek P., Meuwly J.Y., D'Acremont V., Kronenberg A., Locatelli I., Mueller Y., Senn N., Boillat-Blanco N.
ISSN
2079-6382 (Print)
ISSN-L
2079-6382
Publication state
Published
Issued date
02/03/2023
Peer-reviewed
Oui
Volume
12
Number
3
Pages
496
Language
english
Notes
Publication types: Journal Article
Publication Status: epublish
Abstract
Guidelines recommend chest X-rays (CXRs) to diagnose pneumonia and guide antibiotic treatment. This study aimed to identify clinical predictors of pneumonia that are visible on a chest X-ray (CXR+) which could support ruling out pneumonia and avoiding unnecessary CXRs, including oxygen saturation. A secondary analysis was performed in a clinical trial that included patients with suspected pneumonia in Swiss primary care. CXRs were reviewed by two radiologists. We evaluated the association between clinical signs (heart rate > 100/min, respiratory rate ≥ 24/min, temperature ≥ 37.8 °C, abnormal auscultation, and oxygen saturation < 95%) and CXR+ using multivariate analysis. We also calculated the diagnostic performance of the associated clinical signs combined in a clinical decision rule (CDR), as well as a CDR derived from a large meta-analysis (at least one of the following: heart rate > 100/min, respiratory rate ≥ 24/min, temperature ≥ 37.8 °C, or abnormal auscultation). Out of 469 patients from the initial trial, 107 had a CXR and were included in this study. Of these, 26 (24%) had a CXR+. We found that temperature and oxygen saturation were associated with CXR+. A CDR based on the presence of either temperature ≥ 37.8 °C and/or an oxygen saturation level < 95% had a sensitivity of 69% and a negative likelihood ratio (LR-) of 0.45. The CDR from the meta-analysis had a sensitivity of 92% and an LR- of 0.37. The addition of saturation < 95% to this CDR increased the sensitivity (96%) and decreased the LR- (0.21). In conclusion, this study suggests that pulse oximetry could be added to a simple CDR to decrease the probability of pneumonia to an acceptable level and avoid unnecessary CXRs.
Keywords
antibiotics, chest X-ray, clinical decision rule, infiltrate, lower respiratory tract infections, pneumonia, primary care, pulse oximetry, vital signs
Pubmed
Web of science
Open Access
Yes
Create date
03/04/2023 10:42
Last modification date
20/04/2023 6:16
Usage data