Evaluation de deux techniques d'ELISA pour le diagnostic de la paratuberculose bovine

Details

Serval ID
serval:BIB_E9E527BF9841
Type
Article: article from journal or magazin.
Collection
Publications
Title
Evaluation de deux techniques d'ELISA pour le diagnostic de la paratuberculose bovine
Journal
Schweizer Archiv für Tierheilkunde
Author(s)
Meylan M., Nicolet J., Oppliger Anne, Burnens A., Martig J.
ISSN
0036-7281
Publication state
Published
Issued date
1994
Peer-reviewed
Oui
Volume
136
Number
11-12
Pages
377-381
Language
french
Abstract
A sensitivity of 50% and a:specificity of 98% were obtained in the evaluation of a serological method (commercial absorbed ELISA, Commonwealth Serum Laboratories, Parkville, Australia) for the diagnosis of paratuberculosis. The population used in the study consisted of 20 infected suspect and noninfected herds from the region of the Plateau de Diesse. Another evaluated non-absorbed ELISA test had a sensitivity of 30% and a specificity of 91%.
Pubmed
Web of science
Create date
11/10/2011 13:01
Last modification date
20/08/2019 17:12
Usage data