Major acetabular prosthetic protrusion following total hip arthroplasty: a case report of a reconstruction challenge.

Details

Ressource 1Download: 35928578_BIB_E300E227316A.pdf (2027.40 [Ko])
State: Public
Version: Final published version
License: CC BY-NC-ND 4.0
Serval ID
serval:BIB_E300E227316A
Type
Article: article from journal or magazin.
Publication sub-type
Case report (case report): feedback on an observation with a short commentary.
Collection
Publications
Institution
Title
Major acetabular prosthetic protrusion following total hip arthroplasty: a case report of a reconstruction challenge.
Journal
AME case reports
Author(s)
Prod'homme M., Dietrich G., Helfer L., Müller J.P., Barrera Uso M., Grasset D., Lallemand G.
ISSN
2523-1995 (Electronic)
ISSN-L
2523-1995
Publication state
Published
Issued date
2022
Peer-reviewed
Oui
Volume
6
Pages
24
Language
english
Notes
Publication types: Case Reports
Publication Status: epublish
Abstract
Acetabular protrusion is an acetabular defect caused by the shift of the femoral head through the pelvic bone. Because of bone loss, usual anatomical landmarks may be confusing or absent, leading to a particularly high demanding surgical reconstruction in case of total hip arthroplasty (THA) implantation, without adequate support of the acetabulum due to major acetabular defect. To our knowledge, no article has dealt with acetabular defects to this extent and associated femoral osteolysis, which we will attempt to do in this case report. That's why we would like to share this case in order to propose an interesting alternative for the management of these challenging pathologies.
We hereby present the case of a rare pattern of severe acetabular prosthetic protrusion through the pelvic ring on a 77-year-old patient without any trauma. He was surgically treated with acetabular metal augment and a wide femoral modular reconstruction prosthesis. An instability was revealed after 6 weeks, so he underwent an early surgical revision with a constraint cup, overwhelming the absence of abductor apparatus. After this, his recovery was complete and uneventful, with effective function of the reconstructed hip joint and adequate stability of the prosthesis.
Although acetabular protrusion is a rare complication in total hip replacement patients, we would like to draw attention to the challenging nature of this complication, both in terms of initial assessment and surgical management. The described strategy showed effective function of the reconstructed hip joint and final adequate stability of the prosthesis despite the absence of a competent abductor apparatus.
Keywords
Pelvic discontinuity, acetabular protrusion, aseptic loosening, case report, total hip arthroplasty (THA)