Biomechanical effectiveness of a distraction-rotation knee brace in medial knee osteoarthritis: preliminary results

Details

Serval ID
serval:BIB_E21CACBA6B9A
Type
Article: article from journal or magazin.
Collection
Publications
Title
Biomechanical effectiveness of a distraction-rotation knee brace in medial knee osteoarthritis: preliminary results
Journal
Knee
Author(s)
Laroche D., Morisset C., Fortunet C., Gremeaux V., Maillefert J. F., Ornetti P.
ISSN
1873-5800 (Electronic)
ISSN-L
0968-0160
Publication state
Published
Issued date
06/2014
Volume
21
Number
3
Pages
710-6
Language
english
Notes
Laroche, Davy
Morisset, Claire
Fortunet, Clementine
Gremeaux, Vincent
Maillefert, Jean-Francis
Ornetti, Paul
eng
Clinical Trial
Netherlands
Knee. 2014 Jun;21(3):710-6. doi: 10.1016/j.knee.2014.02.015. Epub 2014 Feb 28.
Abstract
BACKGROUND: Non-pharmacological therapies are recommended for the care of knee osteoarthritis patients. Unloader knee braces provide an interesting functional approach, which aims to modulate mechanical stress on the symptomatic joint compartment. We aimed to confirm the biomechanical effects and evaluate functional benefits of a new knee brace that combines a valgus effect with knee and tibial external rotation during gait in medial osteoarthritis patients. METHODS: Twenty patients with unilateral symptomatic medial knee osteoarthritis were included and they performed two test sessions of 3D gait analysis with and without the brace at the initial evaluation (W0) and after 5weeks (W5) of wearing the brace. VAS-pain, satisfaction scores, WOMAC scores, spatio-temporal gait parameters (gait speed, stride length, stance and double stance phases, step width), and biomechanical data of the ipsilateral lower limb (hip, knee, ankle and foot progression angles) were recorded at each session. RESULTS: VAS-pain and WOMAC significantly decreased at W5. Walking speed was not significantly modified by knee bracing at W0, but increased significantly at W5. Knee adduction moments and foot progression angles significantly decreased in the terminal stance and push off, respectively, with bracing at W0 and W5. Lower-limb joint angles, moments and powers were significantly modified by wearing the brace at W0 and W5. CONCLUSION: This new knee brace with distraction-rotation effects significantly alters knee adduction moments and foot progression angles during gait, which might lead to significant functional gait improvements and have carry-over effects on pain at the short term in osteoarthritis patients (<2 months). LEVEL OF EVIDENCE: level IV.
Keywords
Biomechanical Phenomena/physiology, *Braces, Equipment Design, Female, Gait/*physiology, Humans, Locomotion/*physiology, Male, Middle Aged, Osteoarthritis, Knee/physiopathology/*therapy, Patient Satisfaction, Prospective Studies, Visual Analog Scale, Biomechanics, Knee brace, Knee osteoarthritis, Locomotion
Pubmed
Create date
26/11/2019 11:35
Last modification date
06/05/2020 5:26
Usage data