Intramuscular Stem Cell Injection in Combination with Bioengineered Nerve Repair or Nerve Grafting Reduces Muscle Atrophy.
Details
Serval ID
serval:BIB_DA0AE6F776CA
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Intramuscular Stem Cell Injection in Combination with Bioengineered Nerve Repair or Nerve Grafting Reduces Muscle Atrophy.
Journal
Plastic and reconstructive surgery
ISSN
1529-4242 (Electronic)
ISSN-L
0032-1052
Publication state
Published
Issued date
01/05/2022
Peer-reviewed
Oui
Volume
149
Number
5
Pages
905e-913e
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Publication Status: ppublish
Abstract
Peripheral nerve injuries represent a clinical challenge, especially when they are accompanied by loss of neural tissue. In this study, the authors attempted to attain a better outcome after a peripheral nerve injury by both repairing the nerve lesion and treating the denervated muscle at the same time.
Rat sciatic nerves were transected to create 10-mm gaps. Repair was performed in five groups (n = 5 rats for each), as follows: group 1, nerve repair using poly-3-hydroxybutyrate strips to connect the proximal and distal stumps, in combination with control growth medium injection in the gastrocnemius muscle; group 2, nerve repair with poly-3-hydroxybutyrate strip seeded with Schwann cell-like differentiated adipose stem cells (differentiated adipose stem cell strip) in combination with growth medium intramuscular injection; group 3, differentiated adipose stem cell strip in combination with intramuscular injection of differentiated adipose stem cells; group 4, repair using autograft (reverse sciatic nerve graft) in combination with intramuscular injection of growth medium; and group 5, autograft in combination with intramuscular injection of differentiated adipose stem cells. Six weeks after nerve injury, the effects of the stem cells on muscle atrophy were assessed.
Poly-3-hydroxybutyrate strips seeded with differentiated adipose stem cells showed a high number of βIII-tubulin-positive axons entering the distal stump and abundant endothelial cells. Group 1 animals exhibited more muscle atrophy than all the other groups, and group 5 animals had the greatest muscle weights and muscle fibers size.
Bioengineering nerve repair in combination with intramuscular stem cell injection is a promising technique to treat nerve lesions and associated muscle atrophy.
Nerve injuries and resulting muscle atrophy are a clinical challenge. To optimize functional recovery after a nerve lesion, the authors treated the nerve and muscle at the same time by using regenerative medicine with adipose stem cells and obtained encouraging results for future clinical applications.
Rat sciatic nerves were transected to create 10-mm gaps. Repair was performed in five groups (n = 5 rats for each), as follows: group 1, nerve repair using poly-3-hydroxybutyrate strips to connect the proximal and distal stumps, in combination with control growth medium injection in the gastrocnemius muscle; group 2, nerve repair with poly-3-hydroxybutyrate strip seeded with Schwann cell-like differentiated adipose stem cells (differentiated adipose stem cell strip) in combination with growth medium intramuscular injection; group 3, differentiated adipose stem cell strip in combination with intramuscular injection of differentiated adipose stem cells; group 4, repair using autograft (reverse sciatic nerve graft) in combination with intramuscular injection of growth medium; and group 5, autograft in combination with intramuscular injection of differentiated adipose stem cells. Six weeks after nerve injury, the effects of the stem cells on muscle atrophy were assessed.
Poly-3-hydroxybutyrate strips seeded with differentiated adipose stem cells showed a high number of βIII-tubulin-positive axons entering the distal stump and abundant endothelial cells. Group 1 animals exhibited more muscle atrophy than all the other groups, and group 5 animals had the greatest muscle weights and muscle fibers size.
Bioengineering nerve repair in combination with intramuscular stem cell injection is a promising technique to treat nerve lesions and associated muscle atrophy.
Nerve injuries and resulting muscle atrophy are a clinical challenge. To optimize functional recovery after a nerve lesion, the authors treated the nerve and muscle at the same time by using regenerative medicine with adipose stem cells and obtained encouraging results for future clinical applications.
Keywords
Animals, Endothelial Cells/pathology, Humans, Injections, Intramuscular, Muscle, Skeletal/pathology, Muscular Atrophy/etiology, Muscular Atrophy/prevention & control, Nerve Regeneration/physiology, Peripheral Nerve Injuries/pathology, Peripheral Nerve Injuries/surgery, Rats, Sciatic Nerve/injuries, Sciatic Nerve/surgery, Stem Cells/pathology
Pubmed
Web of science
Create date
21/03/2022 9:20
Last modification date
04/11/2023 7:08