Dual Layer vs Single Layer Woven EndoBridge Device in the Treatment of Intracranial Aneurysms: A Propensity Score-Matched Analysis.

Details

Serval ID
serval:BIB_D11BAA63B32A
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Dual Layer vs Single Layer Woven EndoBridge Device in the Treatment of Intracranial Aneurysms: A Propensity Score-Matched Analysis.
Journal
Neurosurgical review
Author(s)
Dmytriw A.A., Salim H., Musmar B., Aslan A., Cancelliere N.M., McLellan R.M., Algin O., Ghozy S., Dibas M., Lay S.V., Guenego A., Renieri L., Carnevale J., Saliou G., Mastorakos P., Naamani K.E., Shotar E., Premat K., Möhlenbruch M., Kral M., Doron O., Chung C., Salem M.M., Lylyk I., Foreman P.M., Vachhani J.A., Shaikh H., Župančić V., Hafeez M.U., Catapano J., Waqas M., Tutino V.M., Ibrahim M.K., Mohammed M.A., Imamoglu C., Bayrak A., Rabinov J.D., Ren Y., Schirmer C.M., Piano M., Kühn A.L., Michelozzi C., Elens S., Starke R.M., Hassan A.E., Ogilvie M., Sporns P., Jones J., Brinjikji W., Nawka M.T., Psychogios M., Ulfert C., Diestro JDB, Pukenas B., Burkhardt J.K., Huynh T., Martinez-Gutierrez J.C., Essibayi M.A., Sheth S.A., Spiegel G., Tawk R., Lubicz B., Panni P., Puri A.S., Pero G., Nossek E., Raz E., Killer-Oberfalzer M., Griessenauer C.J., Asadi H., Siddiqui A., Brook A.L., Altschul D., Ducruet A.F., Albuquerque F.C., Regenhardt R.W., Stapleton C.J., Kan P., Kalousek V., Lylyk P., Boddu S., Knopman J., Aziz-Sultan M.A., Tjoumakaris S.I., Clarençon F., Limbucci N., Cuellar-Saenz H.H., Jabbour P.M., Pereira V.M., Patel A.B., Adeeb N.
ISSN
1437-2320 (Electronic)
ISSN-L
0344-5607
Publication state
Published
Issued date
14/03/2024
Peer-reviewed
Oui
Volume
47
Number
1
Pages
116
Language
english
Notes
Publication types: Multicenter Study ; Journal Article
Publication Status: epublish
Abstract
The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms.
A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture.
Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23).
The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.
Keywords
Humans, Treatment Outcome, Intracranial Aneurysm/surgery, Intracranial Aneurysm/etiology, Embolization, Therapeutic/adverse effects, Propensity Score, Retrospective Studies, Cohort Studies, Endovascular Procedures/adverse effects, Aneurysms, Intracranial, WEB, Woven EndoBridge, treatment
Pubmed
Web of science
Create date
18/03/2024 17:47
Last modification date
26/03/2024 8:10
Usage data