Effect of renal clearance and continuous renal replacement therapy on appropriateness of recommended meropenem dosing regimens in critically ill patients with susceptible life-threatening infections.

Details

Serval ID
serval:BIB_C826664F7442
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Effect of renal clearance and continuous renal replacement therapy on appropriateness of recommended meropenem dosing regimens in critically ill patients with susceptible life-threatening infections.
Journal
The Journal of antimicrobial chemotherapy
Author(s)
Burger R. (co-first), Guidi M. (co-first), Calpini V., Lamoth F., Decosterd L., Robatel C., Buclin T., Csajka C. (co-last), Marchetti O. (co-last)
ISSN
1460-2091 (Electronic)
ISSN-L
0305-7453
Publication state
Published
Issued date
01/12/2018
Peer-reviewed
Oui
Volume
73
Number
12
Pages
3413-3422
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
Meropenem plasma concentration above a pathogen's MIC over the whole dosing interval (100% ƒT>MIC) is a determinant of outcome in severe infections. Significant variability of meropenem pharmacokinetics is reported in ICU patients.
To characterize meropenem pharmacokinetics in variable CLCR or renal replacement therapy and assess the appropriateness of recommended regimens for MIC coverage.
A pharmacokinetic analysis (NONMEM) was conducted with external model validation. Patient characteristics were tested on meropenem clearance estimates, differentiated according to the presence/absence of continuous renal replacement therapy (CRRT, CLCRRT or CLno-CRRT). Simulations evaluated the appropriateness of recommended dosing for achieving 100% fT>MIC in 90% of patients.
A total of 101 patients were studied: median 63 years (range 49-70), 56% male, SAPS II 38 (27-48). 32% had a CLCR >60 mL/min, 49% underwent CRRT and 32% presented severe sepsis or septic shock. A total of 127 pathogens were documented: 76% Gram-negatives, 24% Gram-positives (meropenem MIC90 2 mg/L, corresponding to EUCAST susceptibility breakpoint). Three hundred and eighty plasma and 129 filtrate-dialysate meropenem concentrations were analysed: two-compartment modelling best described the data. Predicted meropenem CLno-CRRT was 59% lower in impaired (CLCR 30 mL/min) compared to normal (CLCR 100 mL/min) renal function. Simulations showed that recommended regimens appropriately cover MIC90 in patients with CLCR <60 mL/min. Patients with CLCR of 60 to <90 mL/min need 6 g/day to achieve appropriate coverage. In patients with CLCR ≥90 mL/min, appropriate exposure is achieved with increased dose, frequency of administration and infusion duration, or continuous infusion.
Recommended meropenem regimens are suboptimal in ICU patients with normal or augmented renal clearance. Modified dosing or infusion modalities achieve appropriate MIC coverage for optimized antibacterial efficacy in meropenem-susceptible life-threatening infections.