Contact-force guided single-catheter approach for pulmonary vein isolation: Feasibility, outcomes, and cost-effectiveness

Details

Serval ID
serval:BIB_C298DAB31051
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Contact-force guided single-catheter approach for pulmonary vein isolation: Feasibility, outcomes, and cost-effectiveness
Journal
Heart Rhythm
Author(s)
Pambrun Thomas, Combes Stéphane, Sousa Pedro, Le Bloa Mathieu, El Bouazzaoui Rim, Grand-Larrieu Delphine, Thompson Nathaniel, Martin Ruairidh, Combes Nicolas, Boveda Serge, Haïssaguerre Michel, Albenque Jean-Paul
ISSN
1547-5271
Publication state
Published
Issued date
03/2017
Peer-reviewed
Oui
Volume
14
Number
3
Pages
331-338
Language
english
Abstract
Background: For conventional ablation of paroxysmal atrial fibrillation (AF), an ablation catheter in conjunction with a circular mapping catheter (CMC) is typically used for pulmonary vein isolation (PVI).
Objective: The purpose of this study was to evaluate an approach for PVI with a single contact-force (CF) ablation catheter in terms of procedural reliability, outcomes, and cost-effectiveness.
Methods: One hundred consecutive patients with paroxysmal AF were included in the study. Fifty patients (study group) underwent a CF-guided single-catheter approach, whereby PVI was demonstrated when sequential pacing at 9 equidistant points within the lesion set (carina included) failed to capture the left atrium. For confirmation, PVI was verified with a CMC. In comparison, 50 patients (control group) underwent a conventional PVI ablation guided by a CMC.
Results: Procedure time (101 ± 17 minutes vs 107 ± 15 minutes, P = .11), ablation time (24.2 ± 7.1 minutes vs 22.6 ± 8.8 minutes, P = .37), fluoroscopy time (5.6 ± 2.2 minutes vs 8.3 ± 3.4 minutes, P = .09), and applied CF (17.8 ± 2.6 g vs 18 ± 2.8 g, P = .72) did not reach statistical difference between the study and control groups. CF-guided single-catheter ablation achieved successful PVI in 98% of the study group and a 31% reduction in cost. At 1-year follow-up, sinus rhythm maintenance rate was similar in both groups (86% vs 84%, P = .78).
Conclusion: In paroxysmal AF, a CF-guided single-catheter technique is an effective method for PVI, yielding substantial cost savings and clinical results similar to a conventional approach.
Keywords
Physiology (medical), Cardiology and Cardiovascular Medicine, Antral exit block, Atrial fibrillation, Catheter ablation, Contact-force sensing, Radiofrequency ablation.