Comparative Results From a National Joint Registry Hip Data Set of a New Cross-Linked Annealed Polyethylene vs Both Conventional Polyethylene and Ceramic Bearings.

Details

Serval ID
serval:BIB_BA5C5FDBDF6A
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Comparative Results From a National Joint Registry Hip Data Set of a New Cross-Linked Annealed Polyethylene vs Both Conventional Polyethylene and Ceramic Bearings.
Journal
The Journal of arthroplasty
Author(s)
Epinette J.A., Jolles-Haeberli B.M.
ISSN
1532-8406 (Electronic)
ISSN-L
0883-5403
Publication state
Published
Issued date
07/2016
Peer-reviewed
Oui
Volume
31
Number
7
Pages
1483-1491
Language
english
Notes
Publication types: Comparative Study ; Journal Article
Publication Status: ppublish
Abstract
Major concerns in hip arthroplasty concern the fate of bearing surfaces. Highly cross-linked polyethylene materials (HXLPE) currently demonstrate successful in vitro results with new technical procedures of cross-linking the polyethylene material, whereas processing the polyethylene below its melting temperature to produce so-called "annealed HXLPE" would allow retention of important mechanical properties.
Data released by the National Joint Registry of England and Wales addressing in 45,877 hips the same Trident uncemented cup, allowed us to compare the performance of a consecutive cohort of patients implanted with the newest generation of annealed HXLPE acetabular bearings (X3: 21,470) vs 2 consecutive nonselected cohorts, one with conventional polyethylene (N2vac: 8225) and one with ceramic-on-ceramic (CoC) hip bearings (AL: 16,182). The main end point in survivorship has been first defined as revision for any cause, then for any cause which could be related to a failure of the bearing couple.
At 6-year follow-up, all Trident cups demonstrated encouraging global survival cumulative rates all between 95% and 99%. A first study demonstrated better survivorship with X3-HXLPE liners vs conventional ultrahigh molecular weight polyethylene. On the second parallel study, the cumulative survival rates were better for X3 liners as compared to CoC bearings. Moreover, when ranking the yearly cumulative percent revision rates, again the best results were obtained with X3 liners with small alumina heads (cumulative percent revision rate at 0.298).
Within the frame of this Trident study, the use of this X3 highly cross-linked annealed polyethylene could be considered as a reliable alternate solution to CoC bearings.

Keywords
Aged, Arthroplasty, Replacement, Hip/instrumentation, Biocompatible Materials, Ceramics, Female, Hip Joint/surgery, Hip Prosthesis, Humans, Male, Middle Aged, Polyethylene, Prosthesis Design, Prosthesis Failure, Registries, NJR data set, annealed, ceramic bearings, cross-linked polyethylene, hip arthroplasty, trident acetabular components
Pubmed
Web of science
Create date
09/04/2016 16:18
Last modification date
20/08/2019 16:28
Usage data