Preventing false negatives with high-resolution mass spectrometry: the benzophenone case.

Details

Serval ID
serval:BIB_B508715064DB
Type
Article: article from journal or magazin.
Collection
Publications
Title
Preventing false negatives with high-resolution mass spectrometry: the benzophenone case.
Journal
Rapid communications in mass spectrometry : RCM
Author(s)
Gallart-Ayala H., Nuñez O., Moyano E., Galceran M.T., Martins C.P.
ISSN
1097-0231 (Electronic)
ISSN-L
0951-4198
Publication state
Published
Issued date
30/10/2011
Volume
25
Number
20
Pages
3161-3166
Language
english
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Abstract
Benzophenone (BP) is one of the many contaminants reported as present in foodstuffs due to its migration from food packaging materials. Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is acknowledged in the literature as the method of choice for this analysis. However, cases have been reported where the use of this methodology was insufficient to unambiguously confirm the presence of a contaminant. In previous work performed by the authors, the unequivocal identification of BP in packaged foods was not possible even when monitoring two m/z transitions (precursor ion - product ion), since ion ratio errors higher than 20% were obtained. In order to overcome this analytical problem a fast, sensitive and selective liquid chromatography/high-resolution mass spectrometry (LC/HRMS) methodology has been developed and applied to the analysis of BP in packaged foods. A direct comparison between LC/HRMS and LC/MS/MS data indicated better selectivity when working with LC/HRMS at a resolving power of 50,000 FWHM (full width at half maximum) than when monitoring two m/z transitions by LC/MS/MS. The resolving power used enabled the detection and identification of Harman as the compound impeding the confirmation of BP by LC-MS/MS. Similar quantitative results were obtained by an Orbitrap mass analyser (Exactive™) and a triple quadrupole mass analyser (TSQ Quantum Ultra AM™).

Keywords
Animals, Benzophenones/analysis, Beverages/analysis, Cattle, Chromatography, High Pressure Liquid/methods, Chromatography, High Pressure Liquid/standards, Food Analysis/methods, Food Analysis/standards, Food Packaging, Infant Food/analysis, Milk/chemistry, Reproducibility of Results, Sensitivity and Specificity, Soy Milk/chemistry, Tandem Mass Spectrometry/methods, Tandem Mass Spectrometry/standards
Pubmed
Create date
02/06/2017 14:31
Last modification date
21/08/2019 6:34
Usage data