Carotid-subclavian arteries Index (CSI), a new echocardiographic index to recognize coarctation of the aorta in neonates and infants

Details

Serval ID
serval:BIB_ABA8B7BB02B0
Type
Inproceedings: an article in a conference proceedings.
Publication sub-type
Abstract (Abstract): shot summary in a article that contain essentials elements presented during a scientific conference, lecture or from a poster.
Collection
Publications
Institution
Title
Carotid-subclavian arteries Index (CSI), a new echocardiographic index to recognize coarctation of the aorta in neonates and infants
Title of the conference
39th Annual Meeting Association for European Paediatric Cardiology, Association Européene pour la Cardiologie Pédiatrique
Author(s)
Di Bernardo S., Ott S., Berger F.
Address
Munich, Germany, May 19-22, 2004
ISBN
1047-9511
Publication state
Published
Issued date
2004
Peer-reviewed
Oui
Volume
14
Series
Cardiology in the Young
Pages
14-15
Language
english
Abstract
Introduction:
Coarctation of the aorta is a common congenital heart malformation. Mode of diagnosis changed from clinically to almost exclusively by echocardiogram and MRI. We claim to find a new echocardiographic index, based on simple and reliable morphologic measurements, to facilitate the diagnosis of aortic coarctation in the newborn.We reproduce the same procedure for older child to validate this new index.
Material and Methods:
We reviewed echocardiographic studies of 47 neonates with diagnosis of coarctation who underwent cardiac surgery between January 1997 and February 2003 and compared them with a matched control group. We measured 12 different sites of the aorta, aortic arch and the great vessels on the echocardiographic bands. In a second time we reviewed 23 infants for the same measurements and compare them with a matched control group.
Results:
47 neonates with coarctation were analysed, age 11.8 _ 10 days,weight 3.0 _ 0.6 kg, body surface 0.20 _ 0.02m2. The control group was of 16 newborns aged 15.8 _ 10 days,weight 3.2 _ 0.9 kg and body surface 0.20 _ 0.04m2. A significant difference was noted in many morphologic measurement between the both groups, the most significant being the distance between the left carotid artery and the left subclavian artery (coarctation vs control: 7.3 _ 3mm vs 2.4 _ 0.8mm, p _ 0.0001). We then defined a new index, the carotid-subclavian arteries index (CSI) as the diameter of the distal tranverse aortic arch divided to the distance left carotid artery to left subclavian artery being also significaly different (coarctation vs control: 0.76 _ 0.86 vs 2.95 _ 1.24, p _ 0.0001). With the cutoff value of this index of 1.5 the sensitivity for aortic coarctation was 98% and the specificity of 92%. In an older group of infant with coarctation (16 patients) we apply the same principle and find for a cut-off value of 1.5 a sensitivity of 95% and a specificity of 100%.
Conclusions:
The CSI allows to evaluate newborns and infants for aortic coarctation with simple morphologic measurement that are not depending of the left ventricular function, presence of a patent ductus arteriosus or not. Further aggressive evaluation of these patient with a CSI _ 1.5 is indicated.