Technical Note: Break-even dose level for hypofractionated treatment schedules.

Details

Ressource 1Request a copy Under indefinite embargo.
UNIL restricted access
State: Public
Version: author
License: Not specified
Serval ID
serval:BIB_A85E84A8CBCF
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Technical Note: Break-even dose level for hypofractionated treatment schedules.
Journal
Medical physics
Author(s)
Böhlen T.T., Germond J.F., Bourhis J., Vozenin M.C., Bailat C., Bochud F., Moeckli R.
ISSN
2473-4209 (Electronic)
ISSN-L
0094-2405
Publication state
Published
Issued date
11/2021
Peer-reviewed
Oui
Volume
48
Number
11
Pages
7534-7540
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
To derive the isodose line R relative to the prescription dose below which irradiated normal tissue (NT) regions benefit from a hypofractionated schedule with an isoeffective dose to the tumor. To apply the formalism to clinical case examples.
From the standard biologically effective dose (BED) equation based on the linear-quadratic (LQ) model, the BED of an NT that receives a relative proportion r of the prescribed dose per fraction for a given α/β-ratio of the tumor, (α/β) <sub>T</sub> , and NT, (α/β) <sub>NT</sub> , is derived for different treatment schedules while keeping the BED to the tumor constant. Based on this, the "break-even" isodose line R is then derived. The BED of NT regions that receive doses below R decreases for more hypofractionated treatment schedules, and hence a lower risk for NT injury is predicted in these regions. To assess the impact of a linear behavior of BED for high doses per fraction (>6 Gy), we evaluated BED also using the LQ-linear (LQ-L) model.
The formalism provides the equations to derive the BED of an NT as function of dose per fraction for an isoeffective dose to the tumor and the corresponding break-even isodose line R. For generic α/β-ratios of (α/β) <sub>T </sub> = 10 Gy and (α/β) <sub>NT </sub> = 3 Gy and homogeneous dose in the target, R is 30%. R is doubling for stereotactic treatments for which tumor control correlates with the maximum dose of 100% instead of the encompassing isodose line of 50%. When using the LQ-L model, the notion of a break-even dose level R remains valid up to about 20 Gy per fraction for generic α/β-ratios and .
The formalism may be used to estimate below which relative isodose line R there will be a differential sparing of NT when increasing hypofractionation. More generally, it allows to assess changes of the therapeutic index for sets of isoeffective treatment schedules at different relative dose levels compared to a reference schedule in a compact manner.
Keywords
Dose Fractionation, Radiation, Dose-Response Relationship, Radiation, Humans, Linear Models, Neoplasms/radiotherapy, BED, LQ model, LQ-L model, hypofractionation, isoeffect
Pubmed
Web of science
Open Access
Yes
Create date
12/10/2021 9:55
Last modification date
16/03/2023 7:47
Usage data