Monte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations: Results of an international intercomparison exercise

Details

Ressource 1Download: Monte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations.pdf (7187.32 [Ko])
State: Public
Version: Final published version
License: CC BY-NC-ND 4.0
Serval ID
serval:BIB_98C4EECF87B5
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Monte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations: Results of an international intercomparison exercise
Journal
Radiation Measurements
Author(s)
Huet Christelle, Eakins Jonathan, Zankl Maria, Gómez-Ros José María, Jansen Jan, Moraleda Montserrat, Struelens Lara, Akar Deepak K., Borbinha Jorge, Brkić Hrvoje, Bui Duc Ky, Capello Kevin, Linh Dang Thi My, Desorgher Laurent, Di Maria Salvatore, Epstein Lior, Faj Dario, Fantinova Karin, Ferrari Paolo, Gossio Sebastian, Hunt John, Jovanovic Zoran, Kim Han Sung, Krstic Dragana, Le Ngoc Thiem, Lee Yi-Kang, Murugan Manohari, Nadar Minal Y., Nguyen Ngoc-Quynh, Nikezic Dragoslav, Patni Hemant K., Santos Denison Souza, Tremblay Marilyn, Trivino Sebastian, Tymińska Katarzyna
ISSN
1350-4487
Publication state
Published
Issued date
01/2022
Volume
150
Pages
106695
Language
english
Abstract
This paper summarizes the results of an intercomparison on the use of the ICRP Reference Computational Phantoms with radiation transport codes, which was organized by EURADOS working group 6. Three exercises are described: exposure to an anterior-posterior (AP) photon point source, exposure to an AP neutron point source, and exposure to two typical medical X-ray examinations. The three exercises received 17, 8 and 8 so-lutions, respectively. Participants originated from fifteen different countries, and used a wide range of Monte Carlo codes. Due to difficulties in defining the precise source location unambiguously in the exercise description, agreement to within ~10% of the reference solution was considered satisfactory for a given participant's results. Although some participants provided initial solutions in good agreement with the reference solutions, differences of several tens of percent, or even several orders of magnitude, were exhibited for many of the others. Following feedback and suggestions from the organizers, revised solutions were submitted by some of the participants for the photon exercises; in general, agreement was improved. The overall observations from these three inter comparison exercises are summarized and discussed.
Keywords
Instrumentation, Radiation
Web of science
Open Access
Yes
Create date
17/06/2022 18:44
Last modification date
18/11/2023 8:17
Usage data