High density electric source imaging in childhood-onset epilepsy due to focal cortical dysplasia.

Details

Serval ID
serval:BIB_967EEA8968E5
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
High density electric source imaging in childhood-onset epilepsy due to focal cortical dysplasia.
Journal
Clinical neurophysiology practice
Author(s)
Wanders A., Garibotto V., Spinelli L., Beniczky S., Vulliémoz S., Daniel R.T., Schaller K., Bartoli A., Korff C., Seeck M.
ISSN
2467-981X (Electronic)
ISSN-L
2467-981X
Publication state
Published
Issued date
2022
Peer-reviewed
Oui
Volume
7
Pages
245-251
Language
english
Notes
Publication types: Journal Article
Publication Status: epublish
Abstract
The goal of this study was to investigate the diagnostic utility of electric source imaging (ESI) in the presurgical evaluation of children with focal cortical dysplasia (FCD) and to compare it with other imaging techniques.
Twenty patients with epilepsy onset before 18 years, surgically treated focal epilepsy with a minimal follow-up of 2 years, and histologically proven FCD were retrospectively selected. All patients underwent MRI, positron emission tomography (PET), and 16 patients also had ictal single-photon emission computed tomography (iSPECT). ESI, using EEG with 64 electrodes or more (HD-ESI), was performed in all 20 patients. We determined sensitivity, specificity and accuracy of ESI, and compared its yield to that of other imaging techniques.
Twelve patients were seizure-free post-operatively (60%). Among all patients, highest localization accuracy (80%) was obtained with ESI, followed by PET and iSPECT (75%). When results from ESI and SPECT were concordant 100% of patients achieved Engel I outcome. If ESI and PET showed concordant localization, 90% of patients achieved postoperative seizure freedom.
Our findings demonstrate that HD-ESI allows accurate localization of the epileptogenic zone in patients with FCD.
In combination with other imaging modalities, ESI helps with planning a more accurate surgery and therefore, the chances of postoperative seizure control are higher. Since it is based on EEG recordings, it does not require sedation, which is particularly interesting in pediatric patients. ESI represents an important imaging tool in focal epilepsies due to cortical dysplasia, which might be difficult to detect on standard imaging.
Keywords
Children, Electric source imaging, Epilepsy surgery, Focal cortical dysplasia, Outcome
Pubmed
Web of science
Open Access
Yes
Create date
13/09/2022 15:48
Last modification date
25/11/2023 8:09
Usage data