Comparaison de la brosse a catheter telescopique protege au lavage bronchique dans le diagnostic des infiltrats pulmonaires. [Comparison of the shielded telescoping brush catheter with bronchial lavage in the diagnosis of pulmonary infiltrates]
Details
Serval ID
serval:BIB_86BE900975D0
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Comparaison de la brosse a catheter telescopique protege au lavage bronchique dans le diagnostic des infiltrats pulmonaires. [Comparison of the shielded telescoping brush catheter with bronchial lavage in the diagnosis of pulmonary infiltrates]
Journal
Schweizerische Medizinische Wochenschrift
ISSN
0036-7672 (Print)
Publication state
Published
Issued date
09/1985
Volume
115
Number
39
Pages
1350-2
Notes
Comparative Study
English Abstract
Journal Article --- Old month value: Sep 28
English Abstract
Journal Article --- Old month value: Sep 28
Abstract
The results of cultures from bronchial lavage (BL) were compared with those obtained with a telescoping protected brush catheter (PBC) in 56 nonselected patients presenting with a pulmonary infiltrate of unknown etiology. At the time of bronchoscopy, 34 patients were under antibiotics. In 20 cases, the cultures from PBC and/or BL were positive. On the basis of quantitative bacteriological analysis and medical chart review, we conclude that PBC is more sensitive and more specific than BL for the diagnosis of clinically significant infections of the lower respiratory tract.
Keywords
Adult
Aged
Bacteria/isolation & purification
Bronchi/*microbiology
Bronchoscopy
Catheterization/*methods
Exudates and Transudates/*microbiology
Female
Humans
Irrigation/*methods
Male
Middle Aged
Respiratory Tract Infections/*microbiology