Ocular rigidity evaluation after photorefractive keratectomy: an experimental study.

Details

Serval ID
serval:BIB_7FC5852C8E7A
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Ocular rigidity evaluation after photorefractive keratectomy: an experimental study.
Journal
Journal of refractive surgery
Author(s)
Kymionis G.D., Diakonis V.F., Kounis G., Charisis S., Bouzoukis D., Ginis H., Yoo S., Tsilimbaris M., Pallikaris I.G.
ISSN
1081-597X (Print)
ISSN-L
1081-597X
Publication state
Published
Issued date
02/2008
Peer-reviewed
Oui
Volume
24
Number
2
Pages
173-177
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
To evaluate possible changes of the ocular rigidity coefficient in vivo after photorefractive keratectomy (PRK) in a series of rabbit eyes, using an invasive ocular rigidity measurement device.
Sixteen eyes of 8 rabbits were used in this study. One eye from each rabbit underwent PRK for -10.00 diopters (D) in a 5-mm optical zone (92 microm) while the fellow eye served as the control. Five weeks later, the rabbits were examined under general anesthesia. The pressure-volume relationship and the ocular rigidity coefficient were determined in all 16 eyes, by injecting 200 microL of saline solution (in increments of 4.5 microL) through the limbus into the anterior chamber, while the intraocular pressure (IOP) was continually monitored with a transducer, up to a maximum limit of 40 mmHg. Data within an IOP range of 10 to 40 mmHg were used to calculate the ocular rigidity coefficient.
The preoperative central corneal thickness was comparable (P = .73, paired t test) in the pre-PRK eyes (mean: 347.5 +/- 17.11 microm) and control eyes (mean: 349.1 +/- 17.46 microm). No statistically significant difference was noted in measured ocular rigidity coefficient between eyes treated with PRK and control eyes (mean rigidity coefficient: 0.42 +/- 0.12 mmHg/microL [range: 0.23 to 0.56] and 0.47 +/- 0.12 mmHg/microL [range: 0.28 to 0.62], respectively, with 95% confidence interval of the difference, lower: -0.10 to upper: 0.015, P = .121).
Photorefractive keratectomy did not significantly alter ocular rigidity measurements in this experimental model.