Photoplethysmography-Based Blood Pressure Monitoring Could Improve Patient Outcome during Anesthesia Induction.

Details

Ressource 1Download: 36294710_BIB_7F0388199F94.pdf (1622.06 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_7F0388199F94
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Photoplethysmography-Based Blood Pressure Monitoring Could Improve Patient Outcome during Anesthesia Induction.
Journal
Journal of personalized medicine
Author(s)
Degiorgis Y., Proença M., Ghamri Y., Hofmann G., Lemay M., Schoettker P.
ISSN
2075-4426 (Print)
ISSN-L
2075-4426
Publication state
Published
Issued date
23/09/2022
Peer-reviewed
Oui
Volume
12
Number
10
Pages
1571
Language
english
Notes
Publication types: Journal Article
Publication Status: epublish
Abstract
During anesthesia, noncritical patients are routinely monitored via noninvasive cuff-based blood pressure (BP) monitors. Due to the noncontinuous nature of the monitoring, the BP values of the patient remain unavailable between consecutive cuff measurements, carrying the risk of missing rapid and sudden variations in BP. We evaluated the added value of using a photoplethysmography (PPG)-based continuous BP measurement device in addition to the standard cuff-based monitoring in a cohort of 40 patients in comparison with the current approach, in which only intermittent cuff-based measurements are available. When using a three-minute cuff measurement interval, using the PPG-based BP measurement in addition to the cuff-based monitor reduced the error (mean ± SD) of systolic (SBP) and mean (MBP) BP from 2.6 ± 19.6 mmHg and 1.2 ± 13.2 mmHg to 0.5 ± 11.2 mmHg and 0.0 ± 8.1 mmHg, respectively. Error grid analysis was also used to assess the improvement in patient safety. The additional use of the PPG-based BP measurement reduced the amount of data falling into higher risk categories. For SBP, points falling in the significant-, moderate-, and low-risk categories decreased from 1.1%, 8.7%, and 19.3% to 0.0%, 2.3%, and 9.6%, respectively. Similar results were obtained for MBP. These results suggest that using a PPG-based BP monitor-in addition to the standard cuff-based monitor-can improve patient safety during anesthesia induction, with no additional sensor needed.
Keywords
cuffless blood pressure, optical blood pressure, photoplethysmography