Optimization of a method to detect levothyroxine and related compounds in serum and urine by liquid chromatography coupled to triple quadrupole mass spectrometry.

Details

Serval ID
serval:BIB_7176D102D9DB
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Optimization of a method to detect levothyroxine and related compounds in serum and urine by liquid chromatography coupled to triple quadrupole mass spectrometry.
Journal
Journal of pharmacological and toxicological methods
Author(s)
Martínez Brito D., Leogrande P., de la Torre X., Botrè F.
ISSN
1873-488X (Electronic)
ISSN-L
1056-8719
Publication state
Published
Issued date
2022
Peer-reviewed
Oui
Volume
115
Pages
107169
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
Thyroid hormones and their derivatives are structurally related to the non-essential amino acid tyrosine (4-hydroxyphenylalanine). However, there are physicochemical differences that make it difficult to apply an analytical method for their simultaneous detection. This work focused on the optimization of a method using liquid chromatography-electrospray ionization mass spectrometry to measure eight compounds related to levothyroxine (T4). In addition, the influence of the additives to the mobile phase, the solvents for liquid-liquid extraction and the influence of the hydrolysis of the conjugated analytes were studied. Optimization of MRM transitions and collision energy for analytes and capillary voltage, nebulizer gas pressure, nozzle voltage, sheath gas flow, sheath gas temperature, drying gas flow and drying gas temperature for ionization source was done. The recovery of analytes was studied using five solvents and six solvent systems to introduce them into the liquid-liquid extraction and matrix cleanup steps. Different additives to the mobile phase were evaluated as well as the effectiveness of enzymatic and chemical hydrolysis. The best MRM transitions and source parameters were settled in order to generate an optimized instrumental method. The addition of ammonium formate, ammonium fluoride, and acetic acid to the mobile phase showed no improvement in responses compared to classic 0.1% formic acid. The use of tert-butyl methyl ether: isopropanol (75: 25, V: V) showed a suitable recovery of analytes to perform a liquid-liquid extraction, and n-hexane might be an appropriate solvent if a cleanup step is needed. The stability of T3, T4 and thyronine, checked after the hydrolysis with extracts of E. coli and H. pomatia showed good results, contrary to chemical hydrolysis that showed a total degradation of T3 and T4.
Keywords
Chromatography, High Pressure Liquid/methods, Chromatography, Liquid, Escherichia coli, Solvents, Spectrometry, Mass, Electrospray Ionization, Thyroxine, Enzymatic hydrolysis, LC-MS, Levothyroxine, Optimization, Serum, Thyroid hormones, Urine
Pubmed
Web of science
Create date
09/04/2022 19:14
Last modification date
05/05/2023 6:57
Usage data