How we perform myocardial perfusion with cardiovascular magnetic resonance.

Details

Serval ID
serval:BIB_6E826FC0500E
Type
Article: article from journal or magazin.
Publication sub-type
Review (review): journal as complete as possible of one specific subject, written based on exhaustive analyses from published work.
Collection
Publications
Title
How we perform myocardial perfusion with cardiovascular magnetic resonance.
Journal
Journal of Cardiovascular Magnetic Resonance
Author(s)
Gebker R., Schwitter J., Fleck E., Nagel E.
ISSN
1097-6647 (Print)
ISSN-L
1097-6647
Publication state
Published
Issued date
2007
Volume
9
Number
3
Pages
539-547
Language
english
Notes
Publication types: Journal Article ; Review
Abstract
Cardiovascular magnetic resonance first-pass perfusion imaging has developed considerably over the past decade. Several studies have shown that this technique is accurate for the detection of myocardial ischemia. In this article we outline the procedure of myocardial perfusion imaging with cardiovascular magnetic resonance as it is performed at our centers, describe the sequences that are currently used in more detail, review our process of image interpretation, and highlight potential pitfalls that we have encountered in our experience with performing this technique in over 2000 patients.
Keywords
Cardiotonic Agents/pharmacology, Contrast Media, Coronary Circulation/physiology, Humans, Image Processing, Computer-Assisted/methods, Magnetic Resonance Imaging/methods, Myocardial Ischemia/diagnosis, Myocardial Ischemia/physiopathology, Safety
Pubmed
Web of science
Create date
07/09/2011 20:35
Last modification date
20/08/2019 15:27
Usage data