Graft patency after FFR-guided versus angiography-guided coronary artery bypass grafting: the GRAFFITI trial.

Details

Serval ID
serval:BIB_4A7E10D1AD11
Type
Article: article from journal or magazin.
Collection
Publications
Title
Graft patency after FFR-guided versus angiography-guided coronary artery bypass grafting: the GRAFFITI trial.
Journal
EuroIntervention
Author(s)
Toth G.G., De Bruyne B., Kala P., Ribichini F.L., Casselman F., Ramos R., Piroth Z., Fournier S., Piccoli A., Van Mieghem C., Penicka M., Mates M., Nemec P., Van Praet F., Stockman B., Degriek I., Barbato E.
ISSN
1969-6213 (Electronic)
ISSN-L
1774-024X
Publication state
Published
Issued date
06/12/2019
Peer-reviewed
Oui
Volume
15
Number
11
Pages
e999-e1005
Language
english
Notes
Publication types: Journal Article ; Randomized Controlled Trial
Publication Status: epublish
Abstract
The aim of this study was to assess prospectively the clinical benefits of fractional flow reserve (FFR) in guiding coronary artery bypass grafting (CABG).
GRAFFITI is a single-blinded, prospective, multicentre, randomised controlled trial of FFR-guided versus angiography-guided CABG. We enrolled patients undergoing coronary angiography, having a significantly diseased left anterior descending artery or left main stem and at least one more major coronary artery with intermediate stenosis, assessed by FFR. Surgical strategy was defined based on angiography, blinded to FFR values prior to randomisation. After randomisation, patients were operated on either following the angiography-based strategy (angiography-guided group) or according to FFR, i.e., with an FFR ≤0.80 as cut-off for grafting (FFR-guided group). The primary endpoint was graft patency at 12 months. Between March 2012 and December 2016, 172 patients were randomised either to the angiography-guided group (84 patients) or to the FFR-guided group (88 patients). The patients had a median of three [3; 4] lesions; diameter stenosis was 65% (50%; 80%), FFR was 0.72 (0.50; 0.82). Compared to the angiography-guided group, the FFR-guided group received fewer anastomoses (3 [3; 3] vs 2 [2; 3], respectively; p=0.004). One-year angiographic follow-up showed no difference in overall graft patency (126 [80%] vs 113 [81%], respectively; p=0.885). One-year clinical follow-up, available in 98% of patients, showed no difference in the composite of death, myocardial infarction, target vessel revascularisation and stroke.
FFR guidance of CABG has no impact on one-year graft patency, but it is associated with a simplified surgical procedure. ClinicalTrials.gov Identifier: NCT01810224.
Keywords
Coronary Angiography, Coronary Artery Bypass, Coronary Artery Disease/surgery, Coronary Stenosis, Fractional Flow Reserve, Myocardial, Humans, Prospective Studies, Treatment Outcome