Variables of interest to predict glomerular filtration rate in preterm newborns in the first days of life.

Details

Serval ID
serval:BIB_464FF560EA14
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Variables of interest to predict glomerular filtration rate in preterm newborns in the first days of life.
Journal
Pediatric nephrology
Author(s)
Wilhelm-Bals A., Combescure C., Chehade H., Daali Y., Parvex P.
ISSN
1432-198X (Electronic)
ISSN-L
0931-041X
Publication state
Published
Issued date
04/2020
Peer-reviewed
Oui
Volume
35
Number
4
Pages
703-712
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
Measurement of neonatal renal function is challenging, and accurate, easy-to-use markers to estimate glomerular filtration rate (eGFR) are lacking. This study aimed to evaluate principal determinants of GFR in neonates and develop a predictive equation.
GFR was measured, using single injection inulin clearance, at median day 3 of life in 48 newborns. Associations of clearance with height, gestational age, weight, creatinine, and cystatin C were explored and a multivariable model to estimate GFR developed. We also evaluated preexisting GFR equations (Schwartz, Zappitelli, combined Zappitelli).
Forty-four clearances were measured, 36 very preterm neonates (28-32 weeks); 5 extremely preterm (< 28 weeks), and 3 term newborns. No patient presented acute renal insufficiency. Median inulin clearance in preterm infants was 18.83 ml/min/1.73 m <sup>2</sup> (IQ 15.29; 24.99). Inulin clearance correlated with weight (ρ 0.74), gestational age (ρ 0.72), height (ρ 0.49), and creatinine (ρ - 0.42), but not cystatin C. In the multivariable model, predicted GFR equation was 2.32* (weight (g)) <sup>0.64</sup> /(creatinine (mcmol/l)) <sup>0.62</sup> . Mean error in predicting clearance was - 0.8 ml/min/1.73 m <sup>2</sup> (- 3.0-1.4) ranging from - 14.9 to 13.3 ml/min/1.73 m <sup>2</sup> . Mean prediction error with Zappitelli and combined Zappitelli equations were 28.5 ml/min/1.73 m <sup>2</sup> (95% CI 24.6-32.3) and 28.3 ml/min/1.73 m <sup>2</sup> (95% CI 24.9-31.7), respectively, and 2 ml/min/1.73 m <sup>2</sup> (95% CI - 0.6-4.6) for Schwartz equation.
Weight and gestational age are crucial determinants of GFR in neonates. The Zappitelli models were not validated in our population. Our predictive model and Schwartz models performed better. Our model should be evaluated in another preterm population, particularly in those presenting renal insufficiency.
Keywords
Estimated glomerular filtration rate, Glomerular filtration rate, Newborns, Preterm