Analyse de la filtration suivant le type d'implants apres sclerectomie profonde chez le lapin. [Analysis of filtration according to implant type after deep sclerectomy in the rabbit]

Details

Serval ID
serval:BIB_4375492E5C7A
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Analyse de la filtration suivant le type d'implants apres sclerectomie profonde chez le lapin. [Analysis of filtration according to implant type after deep sclerectomy in the rabbit]
Journal
Klinische Monatsblatter fur Augenheilkunde
Author(s)
Roy  S., Boldea  R., Nguyen  C., Perez  D., Curchod  M., Mermoud  A.
ISSN
0023-2165 (Print)
Publication state
Published
Issued date
05/2001
Volume
218
Number
5
Pages
354-9
Notes
Comparative Study
English Abstract
Journal Article --- Old month value: May
Abstract
PURPOSE: The purpose of this study was to compare the aqueous humor outflow using three type of implants after deep sclerectomy. A numeric imaging system with ICG and fluorescein angiography was used. The evolution over time was recorded, while filtration and outflow facility were measured. MATERIAL AND METHODS: Numeric imaging system with ICG and fluorescein angiography were performed before and after deep sclerectomy at regular intervals after surgery. Both resorbable (collagen) and non-resorbable (hema) intrascleral devices have been tested in eight rabbits. The resorption time of the collagen implants has been monitored using UBM technique. The outflow facility was measured with the technique of anterior chamber canulation and constant pressure method. RESULTS: The resorbable collagen implants could be observed with UBM and angiography during the first six weeks post-operatively. The image of the non-resorbable Hema implant remained clearly visible over time. New drainage vessels were observed around the filtering bleb. The filtration significantly increased as the outflow facility improved after surgery, while the intraocular pressure remained stable over time. CONCLUSION: This conjunction of UBM, angiography and outflow measurement allowed us to study and compare three types of implants used as space maintainer after deep sclerectomy, and analyse their effect on the aqueous filtration and outflow facility.