Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project

Details

Serval ID
serval:BIB_3F9D7391DA8E
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project
Journal
Radiation Measurements
Author(s)
Vanhavere F., Carinou E., Domienik J., Donadille L., Ginjaume M., Gualdrini G., Koukorava C., Krim S., Nikodemova D., Ruiz-Lopez N., Sans-Merce M., Struelens L.
ISSN
1350-4487 (Print)
Publication state
Published
Issued date
2011
Volume
46
Number
11
Pages
1243-1247
Language
english
Abstract
Within the ORAMED project (Optimization of Radiation Protection of Medical Staff) a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe (www.oramed-fp7.eu). The main objective was to obtain a set of standardized data on extremity and eye lens doses for staff involved in interventional radiology and cardiology and to optimize radiation protection. Special attention was given to the measurement of the doses to the eye lenses. In this paper an overview will be given of the measured eye lens doses and the main influence factors for these doses. The measured eye lens doses are extrapolated to annual doses. The extrapolations showed that monitoringof the eye lens should be performed on routine basis.
Web of science
Create date
15/02/2012 16:50
Last modification date
20/08/2019 14:36
Usage data