Assessment of left coronary artery beat-to-beat repositioning in order to propose an optimal acquisition window for coronary MRA

Details

Ressource 1Download: BIB_349D0121B26A.P001.pdf (2483.26 [Ko])
State: Public
Version: After imprimatur
Serval ID
serval:BIB_349D0121B26A
Type
A Master's thesis.
Publication sub-type
Master (thesis) (master)
Collection
Publications
Institution
Title
Assessment of left coronary artery beat-to-beat repositioning in order to propose an optimal acquisition window for coronary MRA
Author(s)
Firsova M.
Director(s)
Stuber M.
Institution details
Université de Lausanne, Faculté de biologie et médecine
Publication state
Accepted
Issued date
2012
Language
english
Number of pages
23
Abstract
Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA.
Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement.
Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms).
Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.
Keywords
coronary magnetic resonance angiography, acquisition window, beat-to-beat repositioning uncertainty, velocity
Create date
10/09/2013 11:46
Last modification date
20/08/2019 14:21