Contact tracing investigation after professional exposure to tuberculosis in a Swiss hospital using both tuberculin skin test and IGRA.

Details

Ressource 1Download: 25121477.pdf (418.20 [Ko])
State: Public
Version: Final published version
Serval ID
serval:BIB_30003D714DEA
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Contact tracing investigation after professional exposure to tuberculosis in a Swiss hospital using both tuberculin skin test and IGRA.
Journal
Swiss Medical Weekly
Author(s)
Balmelli C., Zysset F., Pagnamenta A., Francioli P., Lazor-Blanchet C., Zanetti G., Zellweger J.P.
ISSN
1424-3997 (Electronic)
ISSN-L
0036-7672
Publication state
Published
Issued date
2014
Peer-reviewed
Oui
Volume
144
Pages
w13988
Language
english
Notes
Publication types: Journal Article Publication Status: epublish
Abstract
SETTING: A 950 bed teaching hospital in Switzerland.
AIM: To describe the result of a contact investigation among health care workers (HCW) and patients after exposure to a physician with smear-positive pulmonary tuberculosis in a hospital setting using standard tuberculin skin tests (TST) and Interferon-gamma release assay (IGRA).
METHOD: HCW with a negative or unknown TST at hiring had a TST two weeks after the last contact with the index case (T0), repeated six weeks later if negative (T6). All exposed HCW had a T-SPOT.TB at T0 and T6. Exposed patients had a TST six weeks after the last contact, and a T-SPOT.TB if the TST was positive.
RESULTS: Among 101 HCW, 17/73 (22%) had a positive TST at T0. TST was repeated in 50 at T6 and converted from negative to positive in eight (16%). Twelve HCW had a positive T-SPOT.TB at T0 and ten converted from negative to positive at T6. Seven HCW with a positive T-SPOT.TB reverted to negative at T6 or at later controls, most of them with test values close to the cut-off. Among 27 exposed patients tested at six weeks, ten had a positive TST, five of them confirmed by a positive T-SPOT.TB.
CONCLUSIONS: HCW tested twice after exposure to a case of smear-positive pulmonary TB demonstrated a possible conversion in 10% with T-SPOT and 16% with TST. Some T-SPOT.TB reverted from positive to negative during the follow-up, mostly tests with a value close to the cut-off. Due to the variability of the test results, it seems advisable to repeat the test with values close to the cut-off before diagnosing the presence of a tuberculous infection.
Pubmed
Web of science
Open Access
Yes
Create date
09/10/2014 18:26
Last modification date
20/08/2019 14:14
Usage data