Résultats cliniques et angiographiques immédiats et à moyen terme après l'implantation de microprothèses endocoronaires AVE chez 140 patients consécutifs. Expérience lausannoise [Immediate and mid-term clinical and angiographic results after implantation of AVE intracoronary micro-stents in 140 consecutive cases. An experience in Lausanne].

Details

Serval ID
serval:BIB_2B5E1558C4AF
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Résultats cliniques et angiographiques immédiats et à moyen terme après l'implantation de microprothèses endocoronaires AVE chez 140 patients consécutifs. Expérience lausannoise [Immediate and mid-term clinical and angiographic results after implantation of AVE intracoronary micro-stents in 140 consecutive cases. An experience in Lausanne].
Journal
Archives des Maladies du Coeur et des Vaisseaux
Author(s)
Debbas N.M., Menafoglio A., Eeckhout E., Stauffer J.C., Vogt P., Kappenberger L., Goy J.J.
ISSN
0003-9683 (Print)
ISSN-L
0003-9683
Publication state
Published
Issued date
09/1997
Volume
90
Number
9
Pages
1223-1229
Language
french
Notes
Publication types: English Abstract ; Journal Article
Publication Status: ppublish
Abstract
Two hundred AVE (Arterial Vascular Engineering) microstents measuring 4 to 30 mm were implanted in 140 patients aged 62 +/- 10 years with Class II to IV angina of the Canadian Cardiovascular Society Classification. The indications were: de novo lesions (30%), suboptimal angioplasty results (54%), acute occlusion (8%) or restenosis (8%). The stents of 3.0 to 4.0 mm diameter were implanted in the left main coronary artery (1%) the left anterior descending artery (20%), the left circumflex artery (19%), the right coronary artery (44%) or a venous bypass graft (7%) after intravenous injection of 15,000 IU of heparin. Daily treatment with aspirin 100 mg and ticlopidine 500 mg was instituted from the day of the procedure. The success rate was 98.5% with only 3 technical failures. The minimal luminal diameter and percentage stenosis ranged from 0.80 +/- 0.2 mm and 74 +/- 13% before to 2.66 +/- 0.38 mm and 15 +/- 7% after the procedure in vessels with an average reference diameter of 3.05 +/- 0.35 mm. There were 3% of stent-related immediate clinical complications. In February 1996, 97 patients had survived 6 months. With a 97% follow-up rate, the clinical event rate was 18%. The angiographic follow-up rate was 70% and the restenosis rate was 27%. The authors conclude that the AVE microstents are easy to implant and provide excellent immediate angiographic results with a low complication rate.
Keywords
Aged, Angioplasty, Balloon, Coronary, Anticoagulants/administration & dosage, Coronary Angiography, Equipment Design, Feasibility Studies, Female, Follow-Up Studies, Humans, Male, Middle Aged, Myocardial Ischemia/mortality, Myocardial Ischemia/therapy, Platelet Aggregation Inhibitors/administration & dosage, Recurrence, Reoperation, Stents/adverse effects, Treatment Outcome
Pubmed
Web of science
Create date
28/01/2008 10:51
Last modification date
20/08/2019 14:10
Usage data