Shape of Pulmonary Artery Doppler Flow Profile and Right Ventricular Hemodynamics in Neonates.

Details

Ressource 1Download: 38052293.pdf (421.28 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_2ACA865A4B7E
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Shape of Pulmonary Artery Doppler Flow Profile and Right Ventricular Hemodynamics in Neonates.
Journal
The Journal of pediatrics
Author(s)
Joye S., Bhattacharya S., Kharrat A., Jasani B., Giesinger R.E., McNamara P.J., Jain A.
ISSN
1097-6833 (Electronic)
ISSN-L
0022-3476
Publication state
Published
Issued date
03/2024
Peer-reviewed
Oui
Volume
266
Pages
113864
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
To characterize pulmonary artery Doppler flow profile (PAFP) patterns among infants receiving care in neonatal intensive care units and to examine the association of PAFP patterns with pulmonary and right ventricular (RV) hemodynamics.
This is a retrospective study at 2 tertiary intensive care units over 4 years that included neonates who demonstrated a complete tricuspid regurgitation envelope on targeted neonatal echocardiography. Separate personnel reviewed TNEs to characterize PAFP patterns, divide cohort into PAFP groups, and measure quantitative indices of RV hemodynamics (RV systolic pressure, pulmonary artery acceleration time and its ratio with RV ejection time, tricuspid annular plane systolic excursion, and RV output), for intergroup comparisons.
We evaluated TNEs from 186 neonates with median gestational age of 28.5 weeks (IQR, 25.9-35.9 weeks). Four distinct PAFP patterns were identified (A) near-isosceles triangle (22%), (B) right-angled triangle (29%), (C) notching (40%), and (D) low peak velocity (<0.4 m/s; 9%). Groups A-C demonstrated a stepwise worsening in all indices of PH, whereas pattern D was associated with lower tricuspid annular plane systolic excursion and RV output. Using common definitions of pulmonary hypertension (PH), pattern A performed best to rule out PH (sensitivity range, 81%-90%) and pattern C for diagnosing PH (specificity range, 63%-78%).
Inspection of PAFP is a simple bedside echocardiography measure that provides clinically meaningful information on underlying RV hemodynamics and may aid in screening and monitoring of patients for PH in intensive care units.
Keywords
Infant, Infant, Newborn, Humans, Pulmonary Artery/diagnostic imaging, Retrospective Studies, Hypertension, Pulmonary/diagnostic imaging, Hemodynamics, Intensive Care Units, Neonatal, neonatal intensive care unit, pulmonary artery doppler flow profile, pulmonary hypertension, right ventricle, targeted neonatal echocardiography
Pubmed
Open Access
Yes
Create date
07/12/2023 16:04
Last modification date
27/02/2024 7:21
Usage data