Uncemented Total Hip Arthroplasty Through the Direct Anterior Approach: Analysis of a Consecutive Series of 275 Hips With a Minimum Follow-Up of 10 Years.

Details

Ressource 1Download: Article - Uncemented Total Hip Arthroplasty Through the Direct Anterior Approach - Analysis of a Consecutive Series of 275 Hips With a Minimum Follow-Up of 10 Years.pdf (555.69 [Ko])
State: Public
Version: Final published version
License: Not specified
Serval ID
serval:BIB_2A028E9240C9
Type
Article: article from journal or magazin.
Collection
Publications
Title
Uncemented Total Hip Arthroplasty Through the Direct Anterior Approach: Analysis of a Consecutive Series of 275 Hips With a Minimum Follow-Up of 10 Years.
Journal
The Journal of arthroplasty
Author(s)
Rahm S., Tondelli T., Steinmetz S., Schenk P., Dora C., Zingg P.O.
ISSN
1532-8406 (Electronic)
ISSN-L
0883-5403
Publication state
Published
Issued date
06/2019
Peer-reviewed
Oui
Volume
34
Number
6
Pages
1132-1138
Language
english
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Abstract
The purpose of this study was to document complications, outcomes, and 10-year survivorship of primary total hip arthroplasty (THA) using a direct anterior approach with an uncemented, straight, hydroxyapatite-coated stem and an uncemented cup.
A retrospective, consecutive series of 275 primary THAs through a direct anterior approach with traction table using Medacta Versafit cup and Quadra-H stem with a minimum of 10-year follow-up was identified. The cumulative 10-year survival of the implants was estimated using Kaplan-Meier estimator. All complications, reoperations, and failures were analyzed. Subjective and clinical outcomes (Subjective Hip Value, Western Ontario and McMaster Universities Osteoarthritis Index, and Harris Hip Score) were measured.
Of 256 patients (275 hips, 143 men and 113 women) with a mean age of 63 (range, 24-85) years, 48 (19%) patients (52 hips) deceased not related to the surgery after a mean time 49 months (range, 3-118) postoperatively. At >10-year follow-up, 9 THAs were revised. The overall implant survival rate was 96.8% (95% confidence interval, 94.4-98.7) at 10 years. One cup and 1 stem were revised because of aseptic loosening. At the last follow-up, the median Subjective Hip Value was 90% (range, 20-100), the Western Ontario and McMaster Universities Osteoarthritis Index score reached a median of 0.2 points (range, 0-6.3), and the median Harris Hip Score points was 99 (range, 29-100).
Primary THA through an anterior minimal invasive approach with the mentioned implants showed low revision rates and good to excellent clinical outcome after at least 10 years.
Keywords
Adult, Aged, Aged, 80 and over, Arthroplasty, Replacement, Hip/methods, Durapatite/chemistry, Female, Follow-Up Studies, Hip Prosthesis, Humans, Male, Middle Aged, Postoperative Period, Prosthesis Design, Prosthesis Failure, Reoperation, Retrospective Studies, Severity of Illness Index, Treatment Outcome, anterior approach, arthritis, primary THA, straight stem, ten year follow up, uncemented
Pubmed
Web of science
Create date
14/03/2019 9:02
Last modification date
24/02/2023 12:48
Usage data