Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.

Details

Serval ID
serval:BIB_28EE994C779C
Type
Article: article from journal or magazin.
Collection
Publications
Title
Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.
Journal
Intensive Care Medicine
Author(s)
Dubourg J., Javouhey E., Geeraerts T., Messerer M., Kassai B.
ISSN
1432-1238 (Electronic)
ISSN-L
0342-4642
Publication state
Published
Issued date
2011
Volume
37
Number
7
Pages
1059-1068
Language
english
Notes
Publication types: Journal Article ; Meta-Analysis ; ReviewPublication Status: ppublish
Abstract
PURPOSE: To evaluate the diagnostic accuracy of ultrasonography of optic nerve sheath diameter (ONSD) for assessment of intracranial hypertension.
METHODS: Systematic review without language restriction based on electronic databases, with manual review of literature and conference proceedings until July 2010. Studies were eligible if they compared ultrasonography of ONSD with intracranial pressure (ICP) monitoring. Data were extracted independently by three authors. Random-effects meta-analysis and meta-regression were performed.
RESULTS: Six studies including 231 patients were reviewed. No significant heterogeneity was detected for sensitivity, specificity, positive and negative likelihood ratios or diagnostic odds ratio. For detection of raised intracranial pressure, pooled sensitivity was 0.90 [95% confidence interval (CI) 0.80-0.95; p for heterogeneity, p (het) = 0.09], pooled specificity was 0.85 (95% CI 0.73-0.93, p (het) = 0.13), and the pooled diagnostic odds ratio was 51 (95% CI 22-121). The area under the summary receiver-operating characteristic (SROC) curve was 0.94 (95% CI 0.91-0.96).
CONCLUSIONS: Ultrasonography of ONSD shows a good level of diagnostic accuracy for detecting intracranial hypertension. In clinical decision-making, this technique may help physicians decide to transfer patients to specialized centers or to place an invasive device when specific recommendations for this placement do not exist.
Keywords
Humans, Intracranial Hypertension/physiopathology, Intracranial Hypertension/ultrasonography, Intracranial Pressure/physiology, Myelin Sheath/ultrasonography, Optic Nerve/physiopathology, Optic Nerve/ultrasonography
Pubmed
Web of science
Create date
03/01/2014 19:52
Last modification date
20/08/2019 14:08
Usage data