Consensus-based technical recommendations for clinical translation of renal BOLD MRI.

Details

Ressource 1Download: 31768797_BIB_2312F5502FE6.pdf (963.46 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_2312F5502FE6
Type
Article: article from journal or magazin.
Publication sub-type
Review (review): journal as complete as possible of one specific subject, written based on exhaustive analyses from published work.
Collection
Publications
Institution
Title
Consensus-based technical recommendations for clinical translation of renal BOLD MRI.
Journal
Magma
Author(s)
Bane O., Mendichovszky I.A., Milani B., Dekkers I.A., Deux J.F., Eckerbom P., Grenier N., Hall M.E., Inoue T., Laustsen C., Lerman L.O., Liu C., Morrell G., Pedersen M., Pruijm M., Sadowski E.A., Seeliger E., Sharma K., Thoeny H., Vermathen P., Wang Z.J., Serafin Z., Zhang J.L., Francis S.T., Sourbron S., Pohlmann A., Fain S.B., Prasad P.V.
ISSN
1352-8661 (Electronic)
ISSN-L
0968-5243
Publication state
Published
Issued date
02/2020
Peer-reviewed
Oui
Volume
33
Number
1
Pages
199-215
Language
english
Notes
Publication types: Journal Article ; Review
Publication Status: ppublish
Abstract
Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.
Keywords
Animals, Biomarkers/metabolism, Consensus, Delphi Technique, Humans, Kidney/diagnostic imaging, Kidney/metabolism, Magnetic Resonance Imaging/standards, Magnetic Resonance Imaging/trends, Reproducibility of Results, Signal-To-Noise Ratio, Surveys and Questionnaires, Translational Medical Research/trends, BOLD MRI, Biomarkers, Imaging, Kidney, Standardization
Pubmed
Web of science
Open Access
Yes
Create date
05/12/2019 23:34
Last modification date
23/11/2022 8:08
Usage data