Using 5D flow MRI to decode the effects of rhythm on left atrial 3D flow dynamics in patients with atrial fibrillation.

Details

Serval ID
serval:BIB_229E12EEB86C
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Using 5D flow MRI to decode the effects of rhythm on left atrial 3D flow dynamics in patients with atrial fibrillation.
Journal
Magnetic resonance in medicine
Author(s)
Ma L., Yerly J., Di Sopra L., Piccini D., Lee J., DiCarlo A., Passman R., Greenland P., Kim D., Stuber M., Markl M.
ISSN
1522-2594 (Electronic)
ISSN-L
0740-3194
Publication state
Published
Issued date
06/2021
Peer-reviewed
Oui
Volume
85
Number
6
Pages
3125-3139
Language
english
Notes
Publication types: Journal Article ; Research Support, N.I.H., Extramural ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Abstract
This study used a 5D flow framework to explore the influence of arrhythmia on thrombogenic hemodynamic parameters in patients with atrial fibrillation (AF).
A fully self-gated, 3D radial, highly accelerated free-running 5D flow sequence with interleaved four-point velocity-encoding was acquired using an in vitro arrhythmic flow phantom and in 25 patients with a history of AF (68 ± 8 y, 6 female). Self-gating signals were used to calculate AF burden, bin data, and tag each k-space line with its RR <sub>Length</sub> . Data were binned as an RR-resolved dataset with four RR-interval bins (RR1-RR4, short-to-long) for compressed sensing reconstruction. AF burden was calculated as interquartile range of all intrascan RR-intervals divided by median RR-interval, and left atrial (LA) stasis as the percent of the cardiac cycle where the velocity was <0.1 m/s.
In vitro results demonstrated successful recovery of RR-binned flow curves using RR-resolved 5D flow compared to a real-time PC reference standard. In vivo, 5D flow was acquired in 8:48 minutes. AF burden was significantly correlated with 5D flow-derived peak (PV) and mean (MV) velocity and stasis (|ρ| = 0.54-0.75, P < .001). Sensitivity analyses determined a threshold for low versus high AF burden at 9.7%. High burden patients had increased LA mean stasis (up to +42%, P < .01), and lower MV and PV (-30%, -40.6%, respectively, P < .01). RR4 deviated furthest from respiratory-resolved reconstruction (end-expiration) with increased mean stasis (7.6% ± 14.0%, P = .10) and decreased PV (-12.7 ± 14.2%, P = .09).
RR-resolved 5D flow can capture temporal and RR-resolved 3D hemodynamics in <10 minutes and offers a novel approach to investigate arrhythmias.
Keywords
Atrial Fibrillation/diagnostic imaging, Blood Flow Velocity, Female, Heart Atria/diagnostic imaging, Humans, Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging, 4D flow, atrial fibrillation, cardiovascular, compressed sensing, self-gating
Pubmed
Web of science
Create date
11/01/2021 13:45
Last modification date
13/01/2024 7:11
Usage data