Whole-heart coronary vein imaging: a comparison between non-contrast-agent- and contrast-agent-enhanced visualization of the coronary venous system.

Details

Serval ID
serval:BIB_2239975B135F
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Whole-heart coronary vein imaging: a comparison between non-contrast-agent- and contrast-agent-enhanced visualization of the coronary venous system.
Journal
Magnetic Resonance In Medicine
Author(s)
Rasche V., Binner L., Cavagna F., Hombach V., Kunze M., Spiess J., Stuber M., Merkle N.
ISSN
0740-3194[print], 0740-3194[linking]
Publication state
Published
Issued date
2007
Volume
57
Number
6
Pages
1019-1026
Language
english
Notes
Publication types: Comparative Study ; Journal Article Publication Status: ppublish
Abstract
The feasibility of three-dimensional (3D) whole-heart imaging of the coronary venous (CV) system was investigated. The hypothesis that coronary magnetic resonance venography (CMRV) can be improved by using an intravascular contrast agent (CA) was tested. A simplified model of the contrast in T(2)-prepared steady-state free precession (SSFP) imaging was applied to calculate optimal T(2)-preparation durations for the various deoxygenation levels expected in venous blood. Non-contrast-agent (nCA)- and CA-enhanced images were compared for the delineation of the coronary sinus (CS) and its main tributaries. A quantitative analysis of the resulting contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in both approaches was performed. Precontrast visualization of the CV system was limited by the poor CNR between large portions of the venous blood and the surrounding tissue. Postcontrast, a significant increase in CNR between the venous blood and the myocardium (Myo) resulted in a clear delineation of the target vessels. The CNR improvement was 347% (P < 0.05) for the CS, 260% (P < 0.01) for the mid cardiac vein (MCV), and 430% (P < 0.05) for the great cardiac vein (GCV). The improvement in SNR was on average 155%, but was not statistically significant for the CS and the MCV. The signal of the Myo could be significantly reduced to about 25% (P < 0.001).
Keywords
Adult, Contrast Media/administration & dosage, Coronary Circulation, Feasibility Studies, Humans, Imaging, Three-Dimensional, Magnetic Resonance Imaging/methods, Male, Middle Aged, Organometallic Compounds/administration & dosage, Veins