Acute hypersensitivity pneumonitis in a paint quality controller : a case report

Details

Serval ID
serval:BIB_1FA7FCF27DB6
Type
Inproceedings: an article in a conference proceedings.
Publication sub-type
Abstract (Abstract): shot summary in a article that contain essentials elements presented during a scientific conference, lecture or from a poster.
Collection
Publications
Institution
Title
Acute hypersensitivity pneumonitis in a paint quality controller : a case report
Title of the conference
Joint Annual Meeting of the Swiss Respiratory Society, Swiss Society of Occupational Medicine, Swiss Paediatric Respiratory Society, Swiss Society for Thoracic Surgery, Davos (Switzerland), April 16/17, 2009
Author(s)
Bieler Gilles, Thorn David, Llano Roberto, Huynh Cong Khanh, Tomicic Catherine, Berode Michèle, Danuser Brigitta
ISBN
1424-7860
Publication state
Published
Issued date
2009
Peer-reviewed
Oui
Volume
139
Series
Swiss Medical Weekly
Pages
16S
Language
english
Notes
SAPHIRID:79012
Abstract
Introduction: Isocyanates are sensitizing chemicals used in various industries such as polyurethane foam production or paint-related purposes. Acting as haptens recognized by T-lymphocytes, they can cause allergic asthma and rarely hypersensitivity pneumonitis (HP). We aim to present a case report of acute HP due to hexamethylene diisocyanate (HDI) in a paint quality controller, a profession not generally considered at a high risk for work-related Isocyanates exposure.
Case report: A 30-yr-old otherwise healthy female, light smoker working as a paint quality controller developed shortness of breath, malaise, sweating and chills at workplace six hours after handling a HDI-based hardener. Upon admission to emergency department, symptoms had progressed to severe respiratory failure. HR computer tomography (HRCT) showed bilateral ground-glass attenuation without pleural effusion. Rapid clinical and radiological improvement occurred under facial oxygen supply and systemic steroid therapy. Occupational medicine investigations revealed regular handling of HDI using latex gloves without respiratory protection. Assessment at workplace showed insufficient air renewal (1.5 times per hour), inadequate local aspiration and HDI exposure at levels of 1-4.25 ppb/m3 (Swiss Occupation Exposure Limit 5 ppb/m3). Biological monitoring after identical work procedure executed by a co-worker showed HDI exposure (5.1 micrograms hexamethylene diamine/g creatinine). Resumption of work was disadvised because of the life-threatening event.
Discussion: The diagnosis of occupational HP is highly supported by classical findings on imagery and typical symptoms occurring within approved latency interval, associated with rapid clinical improvement. Although neither broncho-alveolar lavage nor specific IgG diagnosis (en route) were performed during the acute episode, various blood tests managed to rule out evidence of an infection or autoimmune disease. Other causes of HP seem unlikely as the patient did not have any recurrence of symptoms since absence from work. Workplace evaluation provided significant information on HDI exposure and allowed substantial recommendations to diminish Isocyanate exposure for the 20 still healthy laboratory co-workers. Although the entryways (air or skin) and precise mechanism of toxicity remain unclear, the present case clearly shows that Isocyanates may trigger acute HP in susceptible workers in a profession not generally considered at a high risk.
Keywords
Isocyanates , Asthma , Occupational Exposure
Create date
27/01/2010 13:20
Last modification date
20/08/2019 13:55
Usage data