Noninvasive detection of macrophage-rich atherosclerotic plaque in hyperlipidemic rabbits using "positive contrast" magnetic resonance imaging.

Details

Serval ID
serval:BIB_1D6E72E7F83C
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Noninvasive detection of macrophage-rich atherosclerotic plaque in hyperlipidemic rabbits using "positive contrast" magnetic resonance imaging.
Journal
Journal of the American College of Cardiology
Author(s)
Korosoglou G., Weiss R.G., Kedziorek D.A., Walczak P., Gilson W.D., Schär M., Sosnovik D.E., Kraitchman D.L., Boston R.C., Bulte J.W., Weissleder R., Stuber M.
ISSN
1558-3597[electronic], 0735-1097[linking]
Publication state
Published
Issued date
2008
Volume
52
Number
6
Pages
483-491
Language
english
Notes
Publication types: Journal Article ; Research Support, N.I.H., Extramural ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Abstract
OBJECTIVES: This study was designed to identify macrophage-rich atherosclerotic plaque noninvasively by imaging the tissue uptake of long-circulating superparamagnetic nanoparticles with a positive contrast off-resonance imaging sequence (inversion recovery with ON-resonant water suppression [IRON]). BACKGROUND: The sudden rupture of macrophage-rich atherosclerotic plaques can trigger the formation of an occlusive thrombus in coronary vessels, resulting in acute myocardial infarction. Therefore, a noninvasive technique that can identify macrophage-rich plaques and thereby assist with risk stratification of patients with atherosclerosis would be of great potential clinical utility. METHODS: Experiments were conducted on a clinical 3-T magnetic resonance imaging (MRI) scanner in 7 heritable hyperlipidemic and 4 control rabbits. Monocrystalline iron-oxide nanoparticles (MION)-47 were administrated intravenously (2 doses of 250 mumol Fe/kg), and animals underwent serial IRON-MRI before injection of the nanoparticles and serially after 1, 3, and 6 days. RESULTS: After administration of MION-47, a striking signal enhancement was found in areas of plaque only in hyperlipidemic rabbits. The magnitude of enhancement on magnetic resonance images had a high correlation with the number of macrophages determined by histology (p < 0.001) and allowed for the detection of macrophage-rich plaque with high accuracy (area under the curve: 0.92, SE: 0.04, 95% confidence interval: 0.84 to 0.96, p < 0.001). No significant signal enhancement was measured in remote areas without plaque by histology and in control rabbits without atherosclerosis. CONCLUSIONS: Using IRON-MRI in conjunction with superparamagnetic nanoparticles is a promising approach for the noninvasive evaluation of macrophage-rich, vulnerable plaques.
Keywords
Animals, Arteriosclerosis/complications, Arteriosclerosis/diagnosis, Contrast Media, Ferrosoferric Oxide/diagnostic use, Hyperlipidemias/complications, Macrophages/pathology, Magnetic Resonance Imaging/methods, Male, Nanoparticles/diagnostic use, Rabbits, Risk Assessment, Thromboembolism/etiology
Pubmed
Web of science
Open Access
Yes
Create date
02/03/2010 16:04
Last modification date
20/08/2019 12:53
Usage data