Feasibility of quality indicators on prehospital advanced airway management in a physician-staffed emergency medical service: survey-based assessment of the provider point of view.

Details

Serval ID
serval:BIB_17DF35D9C6C1
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Feasibility of quality indicators on prehospital advanced airway management in a physician-staffed emergency medical service: survey-based assessment of the provider point of view.
Journal
BMJ open
Author(s)
Kottmann A., Pasquier M., Carron P.N., Maudet L., Rouvé J.D., Suppan L., Caillet-Bois D., Riva T., Albrecht R., Krüger A., Sollid SJM
ISSN
2044-6055 (Electronic)
ISSN-L
2044-6055
Publication state
Published
Issued date
07/03/2024
Peer-reviewed
Oui
Volume
14
Number
3
Pages
e081951
Language
english
Notes
Publication types: Journal Article
Publication Status: epublish
Abstract
We aimed to determine the feasibility of quality indicators (QIs) for prehospital advanced airway management (PAAM) from a provider point of view.
The study is a survey based feasibility assessment following field testing of QIs for PAAM.
The study was performed in two physician staffed emergency medical services in Switzerland.
42 of the 44 emergency physicians who completed at least one case report form (CRF) dedicated to the collection of the QIs on PAAM between 1 January 2019 and 31 December 2021 participated in the study.
The data required to calculate the 17 QIs was systematically collected through a dedicated electronic CRF.
Primary outcomes were provider-related feasibility criteria: relevance and acceptance of the QIs, as well as reliability of the data collection. Secondary outcomes were effort to collect specific data and to complete the CRF.
Over the study period, 470 CRFs were completed, with a median of 11 per physician (IQR 4-17; range 1-48). The median time to complete the CRF was 7 min (IQR 3-16) and was considered reasonable by 95% of the physicians. Overall, 75% of the physicians assessed the set of QIs to be relevant, and 74% accepted that the set of QIs assessed the quality of PAAM. The reliability of data collection was rated as good or excellent for each of the 17 QIs, with the lowest rated for the following 3 QIs: duration of preoxygenation, duration of laryngoscopy and occurrence of desaturation during laryngoscopy.
Collection of QIs on PAAM appears feasible. Electronic medical records and technological solutions facilitating automatic collection of vital parameters and timing during the procedure could improve the reliability of data collection for some QIs. Studies in other services are needed to determine the external validity of our results.
Keywords
Humans, Quality Indicators, Health Care, Feasibility Studies, Reproducibility of Results, Emergency Medical Services, Physicians, ACCIDENT & EMERGENCY MEDICINE, Adult intensive & critical care, Quality in health care
Pubmed
Open Access
Yes
Create date
11/03/2024 12:10
Last modification date
12/03/2024 8:09
Usage data