Corneal graft detachment without corneal edema after descemet stripping automated endothelial keratoplasty.

Details

Serval ID
serval:BIB_164D660634C9
Type
Article: article from journal or magazin.
Publication sub-type
Case report (case report): feedback on an observation with a short commentary.
Collection
Publications
Institution
Title
Corneal graft detachment without corneal edema after descemet stripping automated endothelial keratoplasty.
Journal
Cornea
Author(s)
Zafirakis P., Kymionis G.D., Grentzelos M.A., Livir-Rallatos G.
ISSN
1536-4798 (Electronic)
ISSN-L
0277-3740
Publication state
Published
Issued date
04/2010
Peer-reviewed
Oui
Volume
29
Number
4
Pages
456-458
Language
english
Notes
Publication types: Case Reports ; Journal Article
Publication Status: ppublish
Abstract
To report the case of a patient who underwent Descemet stripping automated endothelial keratoplasty complicated by corneal graft detachment without corneal edema.
Case report.
A 60-year-old man with bilateral decompensated endothelium 10 years after cataract extraction and anterior chamber intraocular lens implantation underwent combined anterior chamber intraocular lens explantation with iris-sutured posterior chamber intraocular lens implantation and Descemet stripping automated endothelial keratoplasty on the right eye. On the second postoperative day, the corneal graft was attached. Two weeks postoperatively, slit lamp examination revealed a double anterior chamber resulting from corneal graft detachment. The corneal graft was reattached by repositioning and injecting air. One week later, the corneal graft had detached again, creating a double anterior chamber. No corneal edema was present. Nine months postoperatively, the cornea remained clear, although a double anterior chamber was still evident as a result of the detached corneal graft.
Despite post-Descemet stripping automated endothelial keratoplasty corneal graft detachment, the cornea remained without edema.
Keywords
Anterior Chamber/pathology, Cataract Extraction, Cornea/pathology, Corneal Edema/diagnosis, Corneal Edema/etiology, Descemet Stripping Endothelial Keratoplasty, Humans, Lens Implantation, Intraocular, Male, Middle Aged, Postoperative Complications, Rupture, Spontaneous/diagnosis, Rupture, Spontaneous/etiology, Tomography, Optical Coherence