Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland.

Details

Serval ID
serval:BIB_0D1AF16879C8
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Eye lens monitoring programme for medical staff involved in fluoroscopy guided interventional procedures in Switzerland.
Journal
Physica medica
Author(s)
Nowak M., Sans-Merce M., Lemesre C., Elmiger R., Damet J.
ISSN
1724-191X (Electronic)
ISSN-L
1120-1797
Publication state
Published
Issued date
01/2019
Peer-reviewed
Oui
Volume
57
Pages
33-40
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
Epidemiological studies indicate that radiation damages to the eye lens occurs at lower dose values than previously considered (Worgul et al., 2007; Chodick et al., 2008; Ciraj-Bjelac et al., 2010; Rehani et al., 2011; Vano et al., 2010) [1-5]. The International Commission on Radiological Protection lowered the equivalent dose limit value for the eye lens to 20 mSv/year (ICRP, n.d.) [6]. This new limit has been incorporated into the revised Swiss legislation [7]. Prior this change, it was agreed that if the effective dose limit was respected it would implicitly imply the respect of the limit to the eye lens, for penetrating radiation. The concept had to be reviewed in the light of necessary application of the new eye lens dose limit. The new Swiss legislation proposes to use the value of H <sub>p</sub> (0.07) measured over the protective apron to estimate the eye lens dose. This study aims to investigate the validity of this approach for medical staff during fluoroscopy guided procedures. The results show that the ratio between thorax and eye lens doses varies greatly from one medical speciality to another, but also between surgeons within the same speciality. Moreover, for a given physician, the ratio varied over the periods of surveillance. Those variations confirmed the crucial influence of external parameters related to experience, practice and workload. The surveillance method is appropriate for most of the procedures performed in the department included in this study. Nevertheless, for the particular configuration in urology, the respect of the effective dose limit measured by the routine dosimetry does not allow direct compliance with the dose limit to the eye lens, unless appropriate protective eye wear gear are worn.
Keywords
Fluoroscopy/adverse effects, Humans, Lens, Crystalline/radiation effects, Medical Staff, Occupational Exposure/analysis, Radiation Exposure/analysis, Radiation Monitoring/instrumentation, Radiation Monitoring/methods, Switzerland