Indirect Estimation of Breathing Rate from Heart Rate Monitoring System during Running.

Details

Ressource 1Download: sensors-21-05651-v2.pdf (11211.73 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_0ADF1893BBBB
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Indirect Estimation of Breathing Rate from Heart Rate Monitoring System during Running.
Journal
Sensors
Author(s)
Prigent G., Aminian K., Rodrigues T., Vesin J.M., Millet G.P., Falbriard M., Meyer F., Paraschiv-Ionescu A.
ISSN
1424-8220 (Electronic)
ISSN-L
1424-8220
Publication state
Published
Issued date
22/08/2021
Peer-reviewed
Oui
Volume
21
Number
16
Language
english
Notes
Publication types: Journal Article
Publication Status: epublish
Abstract
Recent advances in wearable technologies integrating multi-modal sensors have enabled the in-field monitoring of several physiological metrics. In sport applications, wearable devices have been widely used to improve performance while minimizing the risk of injuries and illness. The objective of this project is to estimate breathing rate (BR) from respiratory sinus arrhythmia (RSA) using heart rate (HR) recorded with a chest belt during physical activities, yielding additional physiological insight without the need of an additional sensor. Thirty-one healthy adults performed a run at increasing speed until exhaustion on an instrumented treadmill. RR intervals were measured using the Polar H10 HR monitoring system attached to a chest belt. A metabolic measurement system was used as a reference to evaluate the accuracy of the BR estimation. The evaluation of the algorithms consisted of exploring two pre-processing methods (band-pass filters and relative RR intervals transformation) with different instantaneous frequency tracking algorithms (short-term Fourier transform, single frequency tracking, harmonic frequency tracking and peak detection). The two most accurate BR estimations were achieved by combining band-pass filters with short-term Fourier transform, and relative RR intervals transformation with harmonic frequency tracking, showing 5.5% and 7.6% errors, respectively. These two methods were found to provide reasonably accurate BR estimation over a wide range of breathing frequency. Future challenges consist in applying/validating our approaches during in-field endurance running in the context of fatigue assessment.
Keywords
Adult, Algorithms, Heart Rate, Humans, Monitoring, Physiologic, Respiratory Rate, Running, Wearable Electronic Devices, RR intervals (RRi), breathing rate (BR), frequency tracking, heart rate (HR), respiratory sinus arrhythmia (RSA)
Pubmed
Web of science
Open Access
Yes
Create date
04/10/2021 10:36
Last modification date
24/02/2022 7:08
Usage data