Multicentre study on the reproducibility of MALDI-TOF MS for nontuberculous mycobacteria identification.

Details

Ressource 1Request a copy Under indefinite embargo.
UNIL restricted access
State: Public
Version: author
License: CC BY 4.0
Serval ID
serval:BIB_0A7FEDA0D9E4
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Multicentre study on the reproducibility of MALDI-TOF MS for nontuberculous mycobacteria identification.
Journal
Scientific reports
Author(s)
Rodriguez-Temporal D., Alcaide F., Mareković I., O'Connor J.A., Gorton R., van Ingen J., Van den Bossche A., Héry-Arnaud G., Beauruelle C., Orth-Höller D., Palacios-Gutiérrez J.J., Tudó G., Bou G., Ceyssens P.J., Garrigó M., González-Martin J., Greub G., Hrabak J., Ingebretsen A., Mediavilla-Gradolph M.C., Oviaño M., Palop B., Pranada A.B., Quiroga L., Ruiz-Serrano M.J., Rodríguez-Sánchez B.
ISSN
2045-2322 (Electronic)
ISSN-L
2045-2322
Publication state
Published
Issued date
24/01/2022
Peer-reviewed
Oui
Volume
12
Number
1
Pages
1237
Language
english
Notes
Publication types: Journal Article ; Multicenter Study ; Research Support, Non-U.S. Gov't
Publication Status: epublish
Abstract
The ability of MALDI-TOF for the identification of nontuberculous mycobacteria (NTM) has improved recently thanks to updated databases and optimized protein extraction procedures. Few multicentre studies on the reproducibility of MALDI-TOF have been performed so far, none on mycobacteria. The aim of this study was to evaluate the reproducibility of MALDI-TOF for the identification of NTM in 15 laboratories in 9 European countries. A total of 98 NTM clinical isolates were grown on Löwenstein-Jensen. Biomass was collected in tubes with water and ethanol, anonymized and sent out to the 15 participating laboratories. Isolates were identified using MALDI Biotyper (Bruker Daltonics). Up to 1330 MALDI-TOF identifications were collected in the study. A score ≥ 1.6 was obtained for 100% of isolates in 5 laboratories (68.2-98.6% in the other). Species-level identification provided by MALDI-TOF was 100% correct in 8 centres and 100% correct to complex-level in 12 laboratories. In most cases, the misidentifications obtained were associated with closely related species. The variability observed for a few isolates could be due to variations in the protein extraction procedure or to MALDI-TOF system status in each centre. In conclusion, MALDI-TOF showed to be a highly reproducible method and suitable for its implementation for NTM identification.
Keywords
Humans, Nontuberculous Mycobacteria/classification, Nontuberculous Mycobacteria/isolation & purification, Reproducibility of Results, Species Specificity, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
Pubmed
Web of science
Open Access
Yes
Create date
31/01/2022 11:16
Last modification date
20/07/2023 6:57
Usage data